Diagnostics and Troubleshooting 3-31

600-699, Diskette Drive Test Error Codes

The 600 series of diagnostic error codes identifies failures with diskette, diskette drive, or system board functions.

Table 3-8

Diskette Drive Test Error Codes

Error Code

Description

Recommended Action

600-xx

Diskette ID drive types test failed.

1.

Replace the diskette and retest.

601-xx

Diskette format failed.

2.

Check and/or replace the diskette power and

602-xx

Diskette read test failed.

 

signal cables and retest.

3.

Replace the diskette drive and retest.

603-xx

Diskette write/read/compute test

4.

Replace the system board and retest.

 

failed.

604-xx

Diskette random seek test failed.

 

 

605-xx

Diskette ID media failed.

 

 

606-xx

Diskette speed test failed.

 

 

607-xx

Diskette wrap test failed.

 

 

608-xx

Diskette write protect test failed.

 

 

609-xx

Diskette reset controller test

 

 

 

failed.

 

 

610-xx

Diskette change line test failed.

 

 

 

 

 

 

699-xx

Diskette drive/media ID error

1.

Replace the media and retest.

 

 

2.

Run the Configuration Utility and retest.

 

 

 

 

1100-1199, Serial Test Error Codes

The 1100 series of diagnostic error codes identifies failures with serial/parallel interface board or system board functions.

Table 3-9

Serial Test Error Codes

Error Code

Description

Recommended Action

1101-xx

Serial port test failed.

1.

Check the switch settings on the Serial/Parallel

1109-xx

Clock register test failed

 

Interface board (if applicable) and retest.

2.

Replace the Serial/Parallel Interface board

 

 

 

 

 

(if applicable) and retest.

 

 

3.

Replace the system board and retest.

 

 

 

 

Page 85
Image 85
Compaq ML370 manual 600-699, Diskette Drive Test Error Codes, 1100-1199, Serial Test Error Codes