3-8Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-2

POST Error Messages

 

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

A Critical Error

None

A catastrophic system error,

Run Diagnostics. Replace failed

occurred prior to this

 

which caused the server to

assembly as indicated.

power-up

 

crash, has been logged.

 

 

 

 

 

Unsupported

1 long, 1 short

Processor not supported by

Check documentation for

Processor Detected

 

current system ROM

supported processors, and if

System Halted

 

 

supported, remove the

 

 

 

 

processor and update the

 

 

 

 

system to latest ROM.

 

 

 

 

FATAL ROM ERROR:

1 long, 1 short

ROM programmed in factory

Replace the physical ROM part.

The System ROM is

 

incorrectly

 

not properly

 

 

 

programmed

 

 

 

 

 

 

 

 

101

- ROM Error

1 long, 1 short

System ROM checksum

Run Diagnostics. Replace failed

 

 

 

 

assembly as indicated.

 

 

 

 

 

101

- I/O ROM Error

None

Options ROM checksum

Run Diagnostics. Replace failed

 

 

 

 

assembly as indicated.

 

 

 

 

 

102

- System Board

None

DMA, timers, and so on

Replace the system board. Run

Failure

 

 

the Compaq System

 

 

 

 

Configuration Utility.

 

 

 

 

 

104

- ASR-2 Timer

None

System board failure

Run Diagnostics. Replace failed

Failure

 

 

assembly as indicated.

 

 

 

 

 

105

- Current System

2L

Non-booted ROM image is

Flash the ROM utilizing

ROM is corrupt—

 

corrupt

ROMPaq.

now booting

 

 

 

redundant System

 

 

 

ROM

 

 

 

 

 

 

 

 

162

- System

2S

Configuration incorrect

Run the System Configuration

Options Not Set

 

 

Utility and correct.

 

 

 

 

163—Time & Date

2S

Invalid time or date in

Run the System Configuration

Not Set

 

configuration memory

Utility and correct.

 

 

 

 

 

164

- Memory Size

2S

Configuration memory incorrect

Run the System Configuration

Error

 

 

Utility and correct.

 

 

 

 

 

172

- Configuration

None

Nonvolatile configuration corrupt

Run the System Configuration

Nonvolatile Memory

 

or jumper installed

Utility and correct.

Invalid

 

 

 

 

 

 

 

 

173

- Slot ID

None

Board replaced, configuration not

Run the System Configuration

Mismatch

 

updated

Utility and correct.

 

 

 

 

 

174

- Configuration/

None

PCI board not found

Run the System Configuration

Slot Mismatch Device

 

 

Utility and correct.

Not Found

 

 

 

continued

Page 62
Image 62