3-28Compaq ProLiant ML370 Maintenance and Service Guide

200-299, Memory Test Error Codes

The 200 series of diagnostic error codes identifies failures with the memory subsystem.

Table 3-4

Memory Test Error Codes

Error Code

Description

Recommended Action

200-xx

Invalid memory configuration.

Reinsert memory modules in correct location and retest.

 

 

 

 

201-xx

Memory machine ID test failed.

1.

Replace the system ROM and retest.

202-xx

Memory system ROM checksum

2.

Replace the processor board and retest.

 

failed.

3.

Replace the memory expansion board and retest.

 

 

 

 

 

 

203-xx

Memory write/read test failed.

1.

Replace the memory module and retest.

204-xx

Memory address test failed.

2.

Replace the processor board and retest.

205-xx

Walking I/O test failed.

3.

Replace the memory expansion board and retest.

206-xx

Increment pattern test failed

 

 

 

 

 

207-xx

Invalid memory

Replace DIMMs.

 

configuration-check DIMM

 

 

 

installation. DIMMs installed

 

 

 

have 8K refresh.

 

 

 

 

 

 

208-xx

Invalid memory speed detected -

 

check DIMM installation. Slow

 

DIMMs may cause data loss.

Replace DIMMs with timing greater than 60 ns.

209-01

RAM long test failed.

1.

Replace the memory module/board and retest.

209-02

Error while saving test block.

2.

Replace the system board and retest.

209-03

Error while restoring test block.

3.

Replace the memory expansion board and retest.

209-89

ECC error during testing.

 

 

 

 

 

 

210-xx

Random pattern test failed.

1.

Replace the memory module and retest.

 

 

2.

Replace the processor board and retest.

 

 

3.

Replace the memory expansion board and retest.

 

 

 

 

211-01

RAND test failed.

1.

Replace the memory module/board and retest.

211-02

Error while saving test block

2.

Replace the system board and retest.

211-03

Error while restoring test block

 

 

211-04

Insufficient memory to perform the

 

 

 

test

 

 

211-05

Failed inverted pattern compare,

 

 

 

but RAM was correct

 

 

211-89

ECC error during testing

 

 

 

 

 

 

214-01

Data error during noise test

1.

Replace the memory module/board and retest.

214-89

ECC error during testing

2.

Replace the system board and retest.

 

 

 

215

Non-functioning DC-DC converter

Replace the DC-DC converter (Processor Power

 

for processor X

Module).

 

 

 

 

Page 82
Image 82
Compaq ML370 manual 200-299, Memory Test Error Codes