Compaq ML370 manual Slot x drive None, Array reports, Incorrect drive

Models: ML370

1 152
Download 152 pages 12.64 Kb
Page 76
Image 76

3-22Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-2

POST Error Messages continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

*1788 - Slot x drive

None

Drives are not installed in their

array reports

 

original positions, so the drives

incorrect drive

 

have been disabled. See note

replacement. The

 

below.

following SCSI

 

 

drive(s) should have

 

 

been replaced: SCSI

 

 

port (y): SCSI ID (x).

 

 

The following SCSI

 

 

drive(s) were

 

 

incorrectly replaced:

 

 

SCSI port (y):

 

 

SCSI ID (z).

 

 

Select F1 to continue

 

 

drive array will

 

 

remain disabled.

 

 

Select F2 to reset

 

 

configuration—all

 

 

data will be lost.

 

 

Reinstall the drives correctly, as indicated.

Press F1 to restart the computer with the drive array disabled.

—Or—

Press F2 to use the drives as configured and lose all the data on them.

*The 1788 error message might display inadvertently due to a bad power cable connection to the drive, noise on the data cable, or a defective SCSI cable. If this message was due to a bad power cable connection, but not incorrect drive replacement, repair the connection and press F2. If this message is not eliminated by pressing F2, run the Array Diagnostic Utility (ADU) to resolve.

—Or—

If this message was not due to a bad power cable connection, and no drive replacement took place, this could indicate noise on the data cable. Check the cable for proper routing.

—Or—

If this message is due to a defective SCSI cable, replace the cable.

continued