Diagnostics and Troubleshooting 3-19

Table 3-2

POST Error Messages continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

1778 - Slot x Drive

None

This message appears whenever

No action required. This

Array resuming

 

a controller reset or power cycle

message appears whenever a

Automatic Data

 

occurs while Automatic Data

controller reset or power cycle

Recovery process

 

Recovery is in progress.

occurs while Automatic Data

 

 

 

Recovery is in progress.

 

 

 

 

1779 - Slot x Drive

None

Intermittent drive failure and/or

If this message appears and

Array—replacement

 

possible loss of data

drive x (identified by its SCSI ID)

drives detected OR

 

 

has not been replaced, this

previously failed

 

 

indicates an intermittent drive

drive(s) now appear

 

 

failure. This message also

to be operational:

 

 

appears once immediately

Port (y): SCSI ID (x):

 

 

following drive replacement

 

 

whenever data must be restored

Restore data from

 

 

 

 

from backup.

backup if

 

 

 

 

 

replacement drive x

 

 

 

has been installed.

 

 

 

 

 

 

 

1780 - Disk 0 Failure

None

Hard drive/format error

Run Diagnostics. Replace failed

 

 

 

assembly as indicated.

 

 

 

 

1781 - Disk 1 Failure

None

Hard drive/format error

Run Diagnostics. Replace failed

 

 

 

assembly as indicated.

 

 

 

 

1782 - Disk

None

Hard disk drive circuitry error

Run Diagnostics. Replace failed

Controller Failure

 

 

assembly as indicated.

 

 

 

 

1783 - Slot x Drive

None

ROM installation problem or

If this message appears

Array Controller

 

Array Accelerator board problem

immediately following a ROM

Failure

 

 

installation, the ROM is

 

 

 

defective or not installed

 

 

 

properly. Check that the

 

 

 

controller is firmly inserted in its

 

 

 

slot. Try upgrading the System

 

 

 

ROMs. Otherwise, replace the

 

 

 

Integrated Smart Array

 

 

 

Controller.

 

 

 

 

1784 - Slot x Drive

None

Defective drive and/or cables

Check for loose cables. Replace

Array Drive Failure.

 

 

defective drive x and/or

The following SCSI

 

 

cable(s).

drive(s) should be

 

 

 

replaced: SCSI

 

 

 

port (y) SCSI ID (x).

 

 

 

 

 

 

 

 

 

 

continued

Page 73
Image 73
Compaq ML370 No action required. This, Array resuming, Automatic Data Occurs while Automatic Data, Hard drive/format error