Compaq ML370 manual SMART-2 Controller error, Storage System Not, Responding Scsi, Port y Check

Models: ML370

1 152
Download 152 pages 12.64 Kb
Page 71
Image 71

Diagnostics and Troubleshooting 3-17

Table 3-2

POST Error Messages continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

1774 - Slot x Drive

None

SMART-2 Controller error

Data found in Array Accelerator

Array—Obsolete

 

 

is older than data found on

data found in Array

 

 

drives. Press F1 to discard the

Accelerator.

 

 

older data in the Array

Select F1 to discard

 

 

Accelerator and retain the

contents of Array

 

 

newer data on the drives.

Accelerator.

 

 

 

Select F2 to write

 

 

 

contents of Array

 

 

 

Accelerator to drives.

 

 

 

 

 

 

 

1775 - Slot x Drive

None

Storage system problem

Turn off power to system.

Array—ProLiant

 

 

Check external ProLiant power

Storage System Not

 

 

switch – external drives must all

Responding SCSI

 

 

be powered up before or at the

Port (y): Check

 

 

same time as the main system.

storage system

 

 

Check cables. If retry does not

power switch and

 

 

help, try replacing the cable,

cables. Turn the

 

 

ProLiant firmware, ProLiant

system power off

 

 

backplane, or the Smart Array

while checking the

 

 

Controller. Press F1 to resume.

ProLiant power and

 

 

 

cable connections,

 

 

 

then turn the system

 

 

 

power back on to

 

 

 

retry.

 

 

 

 

 

 

 

 

 

 

continued

Page 71
Image 71
Compaq ML370 SMART-2 Controller error, Storage System Not, Responding Scsi, Port y Check, Storage system, While checking