3-40Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-16

ADU Diagnostic Messages continued

Message

Description

Recommended Action

Drive (bay) X is a replacement drive marked OK

This drive has been replaced and

Replace the drive.

marked OK by the firmware. This

 

may occur if a drive has an

 

intermittent failure (for example, if a

 

drive has previously failed, and then

 

when ADU is run, the drive starts

 

working again).

 

Drive (bay) X is

The indicated physical drive has

Replace the drive.

failed

failed.

 

 

 

 

Drive (bay) X is

This drive is being rebuilt from the

Normal operations should resume.

undergoing drive

corresponding mirror or parity data.

 

recovery

 

 

 

 

 

Drive (bay) X

The 210-megabyte hard drive has

Replace the drive.

needs replacing

firmware version 2.30 or 2.31.

 

 

 

 

Drive (bay) X

An error occurred while ADU was

If there were multiple errors, this drive may

upload code not

trying to read the upload code

need to be replaced.

readable

information from this drive.

 

 

 

 

Drive (bay) X

The physical drive was incorrectly

Replace the drive that was incorrectly replaced

was

replaced after another drive failed.

and replace the original drive that failed. Do not

inadvertently

 

run the System Configuration Utility and try to

replaced

 

reconfigure; data will be lost.

 

 

 

Drive Monitoring

ADU unable to get monitor and

Check for other errors (time-outs, and so on). If

features are

performance data due to fatal

no other errors occur, upgrade the firmware to a

unobtainable

command problem such as drive

version that supports monitor and performance,

 

time-out, or unable to get data

if desired.

 

because these features are not

 

 

supported on the controller.

 

 

 

 

Drive Monitoring

The monitor and performance

Run the System Configuration Utility to initialize

is NOT enabled

features have not been enabled on

the monitor and performance features.

for SCSI Port x

this drive.

 

Drive ID x

 

 

 

 

 

Drive time-out

ADU issued a command to a physical

The drive or cable may be bad. Check the other

occurred on

drive and the command was never

error messages on the Diagnostics screen to

physical drive

acknowledged.

determine resolution.

bay X

 

 

 

 

 

Drive X indicates

Message indicates physical drive that

Examine the graphical drive representation on

position Y

appears to be scrambled or in a drive

ADU to determine proper drive locations.

 

bay other than the one for which it

Remove drive X and place it in drive position Y.

 

was originally configured.

Rearrange the drives according to the ADU

 

 

instructions.

 

 

 

Duplicate write

Data could not be written to the Array

Replace the Array Accelerator board.

memory error

Accelerator board in duplicate due to

 

 

the detection of parity errors. This is

 

 

not a data loss situation.

 

continued

Page 94
Image 94
Compaq ML370 This drive has been replaced, Marked OK by the firmware. This May occur if a drive has an, Inadvertently