2-38Compaq ProLiant ML370 Maintenance and Service Guide

Internal Replacement Battery

WARNING: This server contains an internal lithium manganese dioxide battery. There is risk of fire and burns if the battery pack is not handled properly. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

Do not expose to temperatures higher than 60°C.

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the Compaq spare designated for this product.

To install the internal replacement battery:

1.Perform the preparation procedures. See “Powering Down the Server” earlier in this chapter.

2.Open the front bezel (tower model only). See “Front Bezel” earlier in this chapter.

3.Remove the small access panel. See “Small Access Panel” earlier in this chapter.

4.Remove the battery from the system board.

Figure 2-34. Removing the internal replacement battery

5.Install the replacement battery, then run the System Configuration utility to reconfigure the server.

CAUTION: Loss of BIOS Settings will occur when the lithium battery is removed. BIOS settings must be reconfigured whenever the battery is replaced.

CAUTION: Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. In order to forward them to recycling or proper disposal, please use the public collection system or return them to Compaq, your authorized Compaq Partners, or their agents.

Page 54
Image 54
Compaq ML370 manual Internal Replacement Battery, Removing the internal replacement battery