Compaq ML370 Nonfunctioning, PPM DC-DC Converter has, Voltage, Redundancy failed in PPM, Cache

Models: ML370

1 152
Download 152 pages 12.64 Kb
Page 64
Image 64

3-10Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-2

POST Error Messages continued

 

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

215

- Processor

None

PPM (DC-DC Converter) has lost

Run Diagnostics. Replace failed

Power Module has

 

redundancy.

assembly as indicated.

lost Redundancy in

 

 

 

Socket x

 

 

 

 

 

 

 

 

215

- Nonfunctioning

None

PPM (DC-DC Converter) has

Run Diagnostics. Replace failed

Voltage Regulator

 

failed or lost redundancy.

assembly as indicated.

Module for

 

 

 

Processors

 

 

 

 

 

 

 

 

216

- Voltage

None

Redundancy failed in PPM

To restore redundancy, replace

Regulator Module for

 

 

the PPM.

Processor X no

 

 

 

longer redundant

 

 

 

 

 

 

 

 

216

- Processor PPM

None

Indicated PPM (DC-DC Converter)

Replace failed assembly as

has lost Redundancy,

 

has lost redundancy

indicated.

Module X

 

 

 

 

 

 

 

 

218

- Cache

None

Cache accelerators not installed

Check cache accelerator

Accelerators Not

 

or improperly installed

installation.

Installed. System

 

 

 

Halted.

 

 

 

 

 

 

 

 

219

- Tag Update

None

Catastrophic chipset failure

Call Compaq service provider.

Rules SRAM Failure.

 

 

 

System Halted.

 

 

 

 

 

 

 

 

219

- Snoop Rules

None

Catastrophic chipset failure

Call Compaq service provider.

SRAM Failure.

 

 

 

System Halted.

 

 

 

 

 

 

 

 

220

- Cache

None

Cache accelerator in slot x

Check cache accelerator

Accelerator Slot x

 

improperly installed or bad

installation and if properly

Initialization Failed.

 

 

installed, replace.

System Halted.

 

 

 

 

 

 

 

 

221

- Power Fault On

None

A PPM on indicated bus is in a

Run Diagnostics. Replace failed

Processor Bus X

 

failed state.

assembly as indicated.

 

 

 

 

 

301

- Keyboard Error

None

Keyboard failure

Turn off the computer, then

 

 

 

 

reconnect the keyboard.

 

 

 

 

 

301

- Keyboard Error

None

Keyboard failure

Replace the keyboard.

or Test Fixture Installed

continued

Page 64