3-16Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-2

POST Error Messages continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

1768 - Slot x Drive

None

SMART-2 Controller error

No action required. Appears

Array—Resuming

 

 

whenever a controller reset or

logical drive

 

 

power cycle occurs while array

expansion process.

 

 

expansion is in progress.

 

 

 

 

1769 - Slot x Drive

None

SMART-2 Controller error

Data has been lost while

Array—Drive(s)

 

 

expanding the array; therefore,

disabled due to

 

 

the drives have been

failure during

 

 

temporarily disabled. Press F2

expand. Select F1 to

 

 

to accept the data loss and

continue with logical

 

 

re-enable the logical drives.

drives disabled.

 

 

Restore data from backup.

Select F2 to accept

 

 

 

data loss and to

 

 

 

re-enable logical

 

 

 

drives.

 

 

 

 

 

 

 

1770 - Slot x drive

None

Firmware update need indicated

The indicated drives are running

array—critical drive

 

 

firmware that is known to cause

firmware problem

 

 

intermittent problems. Please

detected—please

 

 

use the Compaq Options

upgrade firmware on

 

 

ROMPaq utility to upgrade

the following drive(s)

 

 

firmware on all drives to the

using Options

 

 

latest revision. Press F1 or F2 to

ROMPaq (available

 

 

resume.

from

 

 

 

www.compaq.com):

 

 

 

SCSI port (y) SCSI

 

 

 

ID (x)

 

 

 

(RESUME = F1 or

 

 

 

F2 KEY)

 

 

 

 

 

 

 

1771 - Primary Disk

None

Internal and external hard drive

Run the System Configuration

Port Address

 

controllers are both assigned to

Utility and correct.

Assignment Conflict

 

the primary address.

 

 

 

 

 

1772 - Secondary

None

Address assignment conflict:

Run the System Configuration

Disk Port Address

 

internal and external hard drive

Utility and correct.

Assignment Conflict

 

controllers are both assigned to

 

 

 

the secondary address.

 

 

 

 

 

1773 - Primary Fixed

None

Fixed disk drive error

Run the System Configuration

Disk Port Assignment

 

 

Utility and correct.

Conflict

 

 

 

 

 

 

 

 

 

 

continued

Page 70
Image 70
Compaq ML370 Logical drive, Expansion process Expansion is in progress Slot x Drive, Array-critical drive, Primary Disk