Diagnostics and Troubleshooting 3-9

Table 3-2

POST Error Messages continued

 

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

175

- Configuration/

None

PCI board added, configuration

Run the System Configuration

Slot Mismatch Device

 

not updated

Utility and correct.

Found

 

 

 

 

 

 

 

 

177

- Configuration

None

Incomplete system configuration

Run the System Configuration

Not Complete

 

 

Utility and correct.

 

 

 

 

 

178

- Processor

None

Processor type or step does not

Run the System Configuration

Configuration Invalid

 

match configuration memory

Utility and correct.

 

 

 

 

 

180

- Log

None

N/A

N/A

Reinitialized

 

 

 

 

 

 

 

 

201

- Memory Error

None

RAM failure

Run Diagnostics. Replace failed

 

 

 

 

assembly as indicated.

 

 

 

 

 

203

- Memory

None

RAM failure

Run Diagnostics. Replace failed

Address Error

 

 

assembly as indicated.

 

 

 

 

 

207

- Invalid Memory

None

Memory module installed

Verify placement of memory

Configuration—

 

incorrectly

modules.

Check DIMM [SIMM]

 

 

 

Installation

 

 

 

 

 

 

 

 

208 - Invalid Memory

1 long, 1 short

The speed of the memory is too

Speed—Check

 

slow, where: xx00 = expansion

DIMM [SIMM]

 

board SIMMs are too slow, or

Installation

 

00yy = system board SIMMs are

 

 

too slow. xx and yy have

 

 

corresponding bit set

The speed of the memory modules must be 60 ns. Verify the speed of the memory modules installed and replace.

209

- Memory

1 long, 1 short

Unable to size memory

Check DIMM installation, and if

Detection Failure.

 

 

error persists, call Compaq

Check Memory

 

 

service provider.

Installation

 

 

 

 

 

 

 

 

211

- Cache Switch

None

Switch not set properly during

Verify switch settings.

Set Incorrectly

 

installation or upgrade

 

 

 

 

 

 

212

- System

1 short

Processor in slot x failed

Run Diagnostics and replace

Processor Failed/

 

 

failed processor.

Mapped out

 

 

 

 

 

 

 

 

214

- DC-DC

None

PowerSafe Module (DC-DC

Run Diagnostics. Replace failed

Converter Failed

 

Converter) failed

assembly as indicated.

 

 

 

 

 

214

- Processor PPM

None

Indicated PPM (DC-DC Converter)

Replace failed assembly as

Failed Module X

 

failed

indicated.

continued

Page 63
Image 63
Compaq ML370 Slot Mismatch Device Not updated Utility and correct Found, Not Complete Utility and correct, Processor, Log