3-58Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-19

Compaq System Configuration Utility Pager Settings for Booting into Compaq Utilities continued

Pager Data

Example

Description

 

Setting

 

 

 

 

Network

Compaq

For all Compaq standard network controllers

controller

 

 

 

 

 

Network host

CPQHOU

Enter the network name of the server. Use underscores instead of

name

 

spaces within the namefor example, Compaq_Server. If you are using

 

 

IPX network access to the Compaq Utilities, this server name is used to

 

 

advertise NVT host services. This server name displays in the Compaq

 

 

Insight Manager server list when the program determines it can

 

 

communicate using NVT. Set this name to be the same as the server

 

 

name you assign when the host OS is running.

 

 

 

Network card

Slot #

Select the slot number of the network interface card you wish to use for

slot

 

network access to Compaq Utilities.

 

 

 

Network

ETHERNET_II

Select the frame type for the network. Selections include both Ethernet

frame type

 

and Token Ring topologies.

 

 

 

Network IP

xxx.xxx.xxx.xxx

Enter the IP address for this server in standard dot notation.

address

 

NOTE: This is not used if you select Custom for Network controller. You

 

 

 

 

must enter the IP address in the NET.CFG file that you load into the

 

 

Compaq system partition.

 

 

 

Network IP

xxx.xxx.xxx.xxx

Enter the net mask for this server in standard dot notation.

net mask

 

NOTE: This is not used if you select Custom for network controller. You

 

 

 

 

must enter the IP address in the NET.CFG file that you load into the

 

 

Compaq system partition.

 

 

 

Network IP

xxx.xxx.xxx.xxx

Enter the router to be used for this server in standard dot notation.

router address

 

NOTE: This is not used if you select Custom for network controller. You

 

 

 

 

must enter the IP address in the NET.CFG file that you load into the

 

 

Compaq system partition.

 

 

 

If you configure the server to boot into Compaq Utilities, it prepares for remote communications. You can remotely run Diagnostics software, the Inspect Utility, or the System Configuration Utility using a workstation running terminal emulation software, such as Compaq Insight Manager or PC Anywhere.

Booting into the Operating System

When you enable ASR-2 to restart into the operating system and a critical error occurs, ASR-2 logs the error in Integrated Management Log (IML) and restarts the server. The system ROM pages the designated administrator, and then executes the normal restart process.

IMPORTANT: When you enable ASR-2 to restart into the operating system, Modem Dial-In Status, Network Status, and Modem Dial-Out Status are automatically disabled. In this mode, ASR-2 can page you if a critical error occurs, but you cannot access the server, and the server cannot dial out to a remote workstation.

If the ASR-2 feature cannot restart the server within 10 attempts, it logs a critical error in the Integrated Management Log (IML), restarts the server into the Compaq Utilities, and puts the modem into auto-answer mode.

Page 112
Image 112
Compaq ML370 manual Booting into the Operating System