3-42Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-16

ADU Diagnostic Messages continued

Message

Description

Recommended Action

Logical Drive X This status could be issued for

status = FAILED several reasons. If this logical drive is configured for No Fault Tolerance and one or more drives fail, this status will occur. If mirroring is enabled, and any two mirrored drives fail, this status will occur. If Data Guarding is enabled, and two or more drives fail in this unit, this status will occur. This status may also occur if another configured logical drive is in the WRONG DRIVE REPLACED or LOOSE CABLE DETECTED state.

Check for drive failures, wrong drive replaced, or loose cable messages. If there was a drive failure, replace the failed drive(s), then restore the data for this logical drive from the tape backup. Otherwise, follow the wrong drive replaced or loose cable detected procedures.

Logical Drive X

A physical drive in this logical drive

Replace the failed drive as soon as possible.

status =

has failed. The logical drive is

 

INTERIM

operating in interim recovery mode

 

RECOVERY

and is vulnerable.

 

 

 

 

Logical Drive X

A physical drive has a cabling

Turn the system off and attempt to reattach the

status = LOOSE

problem.

cable onto the drive. If the error recurs, replace

CABLE

 

the cable.

DETECTED

 

 

 

 

 

Logical Drive X

A physical drive in this logical drive

When starting the system, select the "F1rebuild

status = NEEDS

has failed and has now been

drive" option to rebuild the replaced drive.

RECOVER

replaced. This drive needs to be

 

 

rebuilt from the mirror drive or the

 

 

parity data.

 

 

 

 

Logical Drive X

The Intelligent Array Expansion

Check the fans and the operating environment.

status =

System drive temperature is beyond

 

OVERHEATED

safe operating levels and the system

 

 

has shut down to avoid damage.

 

 

 

 

Logical Drive X

The Intelligent Array Expansion

Check the fans and the operating environment.

status =

System drive temperature is beyond

 

OVERHEATING

safe operating levels and the system

 

 

has shut down to avoid damage.

 

 

 

 

Logical Drive X

A physical drive in this logical drive

Nothing needs to be done. Normal operations

status =

has failed and has now been

should resume.

RECOVERING

replaced. The replaced drive is

 

 

rebuilding from the mirror drive or

 

 

the parity data.

 

 

 

 

Logical Drive X

A physical drive in this logical drive

Replace the drive that was incorrectly replaced.

status = WRONG

has failed. The incorrect drive was

Then, replace the original drive that failed with a

DRIVE REPLACED

replaced.

new drive. Do not run the System Configuration

 

 

Utility to reconfigure; data on drive will be lost.

 

 

 

Loose cable

ADU found loose cable. If logical

Power down the system. Check cable(s) for tight

detected—

drives are marked FAILED, those

connection to logical drives. Restart system. If

logical drives

logical drives will be unusable until

same message recurs, cable(s) may be bad.

may be marked

problem corrected.

 

FAILED until

 

 

corrected

 

 