Diagnostics and Troubleshooting 3-41

Table 3-16

ADU Diagnostic Messages continued

Message

Description

Recommended Action

Error occurred reading RIS copy from SCSI Port x Drive ID x

An error occurred while ADU was trying to read the RIS from this drive.

If there were multiple errors, this drive may need to be replaced.

FYI: Drive (bay) X

The installed drive was not supplied

If problems exist with this drive, replace it with

is non-Compaq

by Compaq.

a Compaq drive.

supplied

 

 

 

 

 

Identify

The identify controller data from the

Check the identify controller data under the

controller data

array controller did not match the

Inspect Utility. If the firmware version field is the

did not match

information stored in nonvolatile

only difference between the controller and

with NVRAM

RAM. This could occur if new,

nonvolatile RAM data, this is not a problem.

 

previously configured drives have

Otherwise, run the System Configuration Utility.

 

been placed in a system that has

 

 

also been previously configured. It

 

 

could also occur if the firmware on

 

 

the controller has been upgraded and

 

 

the System Configuration Utility was

 

 

not run.

 

 

 

 

Identify logical

The identify unit data from the array

drive data did

controller did not match with the

not match with

information stored in nonvolatile

NVRAM

RAM. This could occur if new,

 

previously configured drives have

 

been placed in a system that has

 

also been previously configured.

Run the System Configuration Utility to configure the controller and nonvolatile RAM.

Insufficient

The adapter does not have sufficient

Operate the system without the Array

adapter

resources to perform operations to

Accelerator board until the drive rebuild

resources

the Array Accelerator board. Drive

completes.

 

rebuild may be occurring.

 

 

 

 

Less than 75%

Operation of Array Accelerator board

Allow sufficient time for batteries to recharge

batteries at

has been disabled due to less

(36 hours). If batteries have not recharged

sufficient voltage

than 75% of battery packs being at

after 36 hours, replace the Array Accelerator

 

sufficient voltage level.

board.

 

 

 

Less than 75%

Battery pack on Array Accelerator is

Allow sufficient time for batteries to recharge

batteries at

below required voltage levels.

(36 hours). If batteries have not recharged

sufficient

 

after 36 hours, replace the Array Accelerator

voltage. Battery

 

board.

pack X below

 

 

reference

 

 

voltage.

 

 

 

 

 

Logical drive X This logical drive failed due to a

failed due to catastrophic cache error. cache error

Replace the Array Accelerator board and reconfigure using the Array Configuration Utility.

continued

Page 95
Image 95
Compaq ML370 manual Is non-Compaq By Compaq Compaq drive Supplied Identify, Controller data Array controller did not match