3-20Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-2

POST Error Messages continued

 

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

1785 - Drive Array

None

Drive array configuration not

 

not Configured

 

detected

 

(followed by one of

 

 

 

the following):

 

 

 

Run Compaq

 

 

Run the Compaq Array

 

Array

 

 

Configuration Utility.

 

Configuration

 

 

 

 

Utility

 

 

 

No drives

 

 

Turn off system and check SCSI

 

detected

 

 

cable connections to make sure

 

 

 

 

drives are attached properly.

Drive positions

 

 

Run Drive Array Advanced

 

cannot be

 

 

Diagnostics if previous positions

 

changed—Run

 

 

are unknown. Then turn system

 

Drive Array

 

 

power off and move drives to

 

Advanced

 

 

their original positions.

 

Diagnostics if

 

 

 

 

previous

 

 

 

 

positions are

 

 

 

 

unknown. Then

 

 

 

 

turn system

 

 

 

 

power OFF and

 

 

 

 

move drives to

 

 

 

 

their original

 

 

 

 

positions.

 

 

 

Configuration

 

 

To avoid data loss, turn system

 

information

 

 

power off and reattach drives to

 

indicates drive

 

 

the original controller.

 

positions beyond

 

 

 

 

the capability of

 

 

 

 

this controller.

 

 

 

 

This may be due

 

 

 

 

to drive

 

 

 

 

movement from

 

 

 

 

a controller that

 

 

 

 

supports more

 

 

 

 

drives than the

 

 

 

 

current

 

 

 

 

controller.

 

 

 

Configuration

 

 

To avoid data loss, reattach

 

information

 

 

drives to original controller or

 

indicates drives

 

 

upgrade the controller firmware

 

were configured

 

 

to the version on the original

 

on a controller

 

 

controller using Option ROMPaq.

 

with newer

 

 

 

firmware.

Press F1 key to resume.

 

continued

Page 74
Image 74
Compaq ML370 Drives are attached properly, Drive positions Run Drive Array Advanced Cannot be, Changed-Run, Information