3-38Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-16

ADU Diagnostic Messages continued

Message

Description

Recommended Action

Adapter/NVRAM

Nonvolatile RAM has an ID for a

Run the System Configuration Utility.

ID mismatch

different controller from the one

 

 

physically present in the slot.

 

 

 

 

Array Accelerator

Battery is not fully charged.

If 75% of batteries present are fully charged,

battery pack X

 

Array Accelerator is fully operational. If less

not fully charged

 

than 75% of batteries are fully charged, allow

 

 

36 hours to recharge them.

 

 

 

Array Accelerator

Battery pack on Array Accelerator is

Allow enough time for batteries to recharge

battery pack X

below required voltage levels.

(36 hours). If batteries have not recharged

below reference

 

after 36 hours, replace the Array Accelerator

voltage

 

board.

(recharging)

 

 

 

 

 

Board in use by

Array Accelerator memory is in use

Operate system without Array Accelerator board

Expand

by Expand operation.

until Expand operation completes.

operation

 

 

 

 

 

Board not

Array controller configured for use

Attach Array Accelerator board to array

attached

with Array Accelerator board, but one

controller.

 

is not attached.

 

 

 

 

Configuration

ADU detected that nonvolatile RAM

Run the latest version of System Configuration

signature is zero

contains a configuration signature of

Utility to configure the controller and nonvolatile

 

zero. Old versions of the System

RAM.

 

Configuration Utility could cause this.

 

 

 

 

Configuration

Array Accelerator board configured

To recognize the Array Accelerator board, run

signature

for a different array controller board.

the Array Configuration Utility.

mismatch

Configuration signature on Array

 

 

Accelerator board does not match the

 

 

one stored on the array controller

 

 

board.

 

 

 

 

Controller

Controller communication failure

ADU was unable to successfully issue

communication

occurred.

commands to the controller in this slot.

failure occurred

 

 

 

 

 

Controller

Nonvolatile RAM does not contain a

Run the System Configuration Utility to

detected.

configuration for this controller.

configure the nonvolatile RAM.

NVRAM

 

 

configuration not

 

 

present

 

 

 

 

 

Controller

Controller firmware is below the

Run Options ROMPaq to upgrade the controller

firmware needs

latest recommended version.

to the latest firmware revision.

upgrading

 

 

 

 

 

Controller is

Controller is installed in slot for

Install the controller in a different slot and run

located in

special video control signals. If

the System Configuration Utility to configure the

special “video”

controller is used in this slot, LED

controller and nonvolatile RAM. Then run the

slot

indicators on front panel may not

Array Configuration Utility to configure

 

function properly.

controller.

continued