Table 1-7. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Error: Incorrect memory

Mismatched or unmatched DIMMs

Ensure that all pairs of memory modules

configuration. DIMMs must

installed; faulty or improperly seated

are of the same type and size and that

be installed in pairs of

memory module(s).

they are properly installed. See "System

matched memory size,

 

Memory" on page 89. If the problem

speed, and technology.

 

persists, see "Troubleshooting System

 

 

Memory" on page 120.

Error: Memory failure detected. Memory size reduced. Replace the faulty DIMM as soon as possible.

Faulty or improperly seated memory

See "Troubleshooting System Memory"

module(s).

on page 120.

!!*** Error: Remote Access

Remote Access Controller

Controller initialization

initialization failure

failure*** RAC virtual USB

 

devices may not be

 

available...

 

Ensure that the Remote Access Controller is properly installed. See "Installing a RAC Card" on page 80.

FBD training error: The following branch has been disabled: Branch x

The specified branch (channel pair) contains DIMMs that are incompatible with each other.

Ensure that only Dell-qualified memory is used. Dell recommends purchasing memory upgrade kits directly from www.dell.com or your Dell sales agent to ensure compatibility.

Gate A20 failure

Faulty keyboard controller; faulty

See "Getting Help" on page 147.

 

system board.

 

General failure

The operating system is unable to

 

carry out the command.

This message is usually followed by specific information. Note the information, and take the appropriate action to resolve the problem.

Invalid NVRAM

System detected and corrected a

No action is required.

configuration, Resource

resource conflict.

 

Re-allocated

 

 

 

 

 

Keyboard Controller

Faulty keyboard controller; faulty

See "Getting Help" on page 147.

failure

system board

 

 

 

 

Manufacturing mode

System is in manufacturing mode.

Reboot to take the system out of

detected

 

manufacturing mode.

 

 

 

MEMBIST failure - The

Faulty memory module(s).

See "Troubleshooting System Memory"

following DIMM/rank has

 

on page 120.

been disabled by BIOS:

 

 

DIMM x Rank y

 

 

30

About Your System

Page 30
Image 30