26 About Your System
E2111 SBE Log Disable
Crd # DIMM ## The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "##"
represents the DIMM implicated
by the BIOS. If no memory riser
card is present, the "Crd #" string
is left out of the message.
See "Troubleshooting System
Memory" on page120.
E2112 Mem Spare Crd #
DIMM ## The system BIOS has spared the
memory because it has
determined that the memory had
too many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS. If no
memory card is present, the "Crd
#" string is left out of the
message.
See "Troubleshooting System
Memory" on page120.
E2113 Mem Mirror Crd #
DIMM ## & ## The system BIOS has disabled
memory mirroring because it has
determined that one half of the
mirror has had too many errors.
"## & ##" represents the
DIMM pair implicated by the
BIOS. If no memory card is
present, the "Crd #" string is left
out of the message.
See "Troubleshooting System
Memory" on page120.
E2118 Fatal NB Mem CRC One of the connections in the
Fully Buffered DIMM (FBD)
memory subsystem link on the
Northbound side has failed.
See "Troubleshooting System
Memory" on page120.
E2119 Fatal SB Mem CRC One of the connections in the
FBD memory subsystem link on
the Southbound side has failed.
See "Troubleshooting System
Memory" on page120.
I1910 Intrusion System cover has been removed. Information only.
I1911 >3 ERRs Chk Log LCD overflow message.
A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.
Check the SEL for details on the
events.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions
Book.book Page 26 Friday, February 3, 2006 11:09 AM