Smart Inventions 990-2689E manual User Configurable Items

Page 11
USER CONFIGURABLE ITEMS

USER CONFIGURABLE ITEMS

NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE, NETWORK MANAGEMENT CARD,

OPTIONAL SMART SLOT ACCESSORY CARDS OR TERMINAL MODE.

FUNCTION

FACTORY

USER SELECTABLE

DESCRIPTION

DEFAULT

CHOICES

 

 

Automatic Self-Test

Every 14 days

Every 7 days

Set the interval at which the

 

(336 hours)

(168 hours),

UPS will execute a self-test.

 

 

Every 14 days

 

 

 

(336 hours),

 

 

 

On Startup Only,

 

 

 

No Self-Test

 

 

 

 

 

UPS ID

UPS_IDEN

Up to eight characters to

Uniquely identify the UPS, (i.e.

 

 

define the UPS

server name or location) for

 

 

 

network management purposes.

 

 

 

 

Date of Last Battery

Manufacture Date

mm/dd/yy

Reset this date when you replace

Replacement

 

 

the battery modules.

 

 

 

 

Minimum Capacity

0 percent

0, 15, 25, 35, 50, 60, 75,

Specify the percentage to which

Before Return from

 

90 percent

batteries will be charged

Shutdown

 

 

following a low-battery

 

 

 

shutdown before powering

 

 

 

connected equipment.

 

 

 

 

Alarm Delay After

5 second delay

5 second delay,

Mute ongoing alarms or disable

Line Failure

 

30 second delay,

all alarms permanently.

 

 

At Low Battery,

 

 

 

Never

 

 

 

 

 

Shutdown Delay

20 seconds

0, 20, 60, 120, 240, 480,

Set the interval between the time

 

 

720, 960 seconds

when the UPS receives a

 

 

 

shutdown command and the

 

 

 

actual shutdown.

 

 

 

 

Duration of

2 minutes

2, 5, 7, 10, 12, 15, 18,

The low battery warning beeps

Low Battery Warning.

PowerChute

20 minutes.

become continuous when two

 

 

minutes of runtime remains.

 

software provides

 

 

automatic,

 

Change the warning interval to a

 

unattended

 

higher setting if the operating

 

shutdown when

 

system requires a longer interval

 

approximately two

 

for shutdown.

 

minutes of battery

 

 

 

runtime remains.

 

 

 

 

 

 

Synchronized Turn-on

0 seconds

0, 20, 60, 120, 240, 480,

Specify the time the UPS will

Delay

 

720, 960 seconds

wait after the return of utility

 

 

 

power before turn-on (to avoid

 

 

 

branch circuit overloads).

 

 

 

 

9

Image 11
Contents Smart-UPS RT Uninterruptible Power Supply SURT 8000/10000 VA 200-240 VACTower/Rack-Mount 6U English Page Introduction SpecificationsINSTALLATION Read the safety information sheet before installationWiring must be performed by a qualified electrician HardwiringINPUT XLT/XLJ/XLTW MODELSXLI MODEL OUTPUTno pq rs Installing and Connecting the Batteries and Attaching the Front BezelXLJ/XLT/XLTW Input Circuit Breaker 8000/10000 VA XLI/XLJ/XLT/XLTWOutput Circuit Breaker 8000/10000 VASerial Port Use only interface kits supplied or approved by APCExternal Battery Pack ConnectorsOPERATION Troubleshootingaffect the voltage display On Battery OperationOPTIONAL SMART SLOT ACCESSORY CARDS OR TERMINAL MODE USER CONFIGURABLE ITEMSXLI models XLJ modelsXLT models XLTW modelsAdhere to national and local electrical codes when wiring EPO Emergency Power Off Option9 flow control - none Terminal Mode to Configure UPS Parameters9 bits per second 9 data - bits 9 parity - none 9 stop bit Transporting the UPS Replacing the Battery ModulesMAINTENANCE, SERVICE, WARRANTY, AND TRANSPORTING The battery modules may remain in the UPSCAUSE TROUBLESHOOTINGPROBLEM AND POSSIBLE SOLUTIONREPLACE BATTERY LED ILLUMINATES Replace Battery LED flashes andFAULT AND OVERLOAD LEDS ILLUMINATE UPS EMITS A SUSTAINED ALARM TONE FAULT LED ILLUMINATESThe batterys may remain in the UPS ServiceLimited Warranty RADIO FREQUENCY WARNINGS APC Worldwide Customer Support