Uniden UBC3500XLT owner manual

Page 78

Set Delay Time Sets the time the scanner remains in monitor mode after the scanner receives a page and the carrier drops.

1-5 seconds: the scanner resumes standby mode after the carrier drops and the selected time expires.

Infinite: you must press HOLD after a page to resume standby mode.

Off: the scanner resumes standby as soon as the carrier drops after a page.

Set Alert — Sets the alert the scanner uses when it receives an alert.

Alert 1 - 9, Off — scroll to select the alert tone pattern, The scanner sounds each alert as you scroll to its numbered value. If you select Off, the scanner does not sound an alert.

After you select an alert pattern, the scanner prompts for the alert level for a received alert. Level options 1 to 15 sets a fixed audio level independent of the main volume setting. AUTO uses the main volume setting for the alerts.

78

Image 78
Contents UBC3500XLT OWNER’S Manual Precautions Earphone WarningContents Entering/Editing Conventional Channel Groups Contents Introduction Frequency MHz Modulation Step kHz Lower Edge Upper EdgeIntroduction Frequency MHz Modulation Step kHz Lower EdgeFeature Highlights GeneralFeature Highlights Search Priority Using the Multifunction Scroll Control About This ManualEntering Text How the Scanner’s Controls Are Represented in This Manual Menu Program SystemEdit Name Page Understanding Scanning What is Scanning?What is Searching? Understanding the Scanner’s MemoryWhat is CTCSS/DCS? 023 025 026 031 032 036 043 047 Conventional Scanning Simplex OperationWhere To Get More Information Repeater OperationInformation On The Internet Included With Your Scanner Setting Up Your Scanner Using Internal BatteriesSetting Up Your Scanner Using Rechargeable Batteries Using AC Power Removing the Display StickerConnecting an Extension Speaker Connecting the AntennaConnecting an Earphone/Headphone Connecting an Optional AntennaAttaching the Belt Clip Attaching the Wrist StrapLook At The Keypad Hold Pri Look At The Display No/revFunc Using Menu Using FuncBasic Operation Turning On the Scanner and Setting the SquelchOnce. Volume Level and a Basic OperationScanning Systems Selecting Systems to ScanSelecting System Channel Groups Locking/Unlocking SystemsHolding On a Channel Locking/Unlocking ChannelsTemporarily Holding On a System Quick-Storing ChannelsQuickly Recalling Channels Toggling Channel Alpha TagsUsing the Menu Menu Item SubmenuUsing the Menu Displaying System Information SettingsAdjusting the Key Beep Locking/Unlocking the Keypad and ScrollSettings Turning Power Save On or OffUsing the Backlight Priority ScanConnecting Your Scanner to a Personal Computer Setting the Audio AGCAdjusting the Display Contrast Initializing the Scanner’s MemoryUsing the Cloning Options Settings PC ControlMaster scanner Clone Master Press Scan Key Wired CloningWired Clone Slave scanner Clone Slave Press Scan KeyProgramming Radio Systems Programming Radio SystemsProgramming Conventional Systems Program System New SystemEntering/Editing Conventional Channel Groups Program SystemEdit Group New Group Entering/Editing Conventional Channels Edit GroupEdit Channel New Channel Editing the System Quick Key System-Level SettingsEditing the System Name Edit Sys Option Set Quick KeyProgramming/Editing Optional Settings Setting System LockoutSetting the System Hold Time Edit Sys Option Set LockoutEdit Sys Option Set Delay Time Setting the Channel Delay TimeSetting the Data Skip Edit Sys Option Set Data SkipCopying Systems Group-Level SettingsDeleting Systems Entering/Editing the Group NameSetting the Group Quick Key Deleting Groups Channel-Level SettingsSetting Group Lockout Editing the Channel NameEditing Frequencies Edit ChannelInput Frequency Setting Channel Priority Setting Channel AlertSet Alert Setting CTCSS/DCS Set LevelSet CTCSS/DCS Setting the Channel Frequency Modulation Set ModurationSetting Channel Attenuation Setting Channel LockoutSet Attenuator Delete Channel Deleting ChannelsCopying/Pasting Channels Copy ChannelEdit Channel Paste Channel Changing the step of Air Band Service SearchSearching and Storing Quick SearchCustom Search Search for Custom SearchEditing a Custom Search Range Search for Edit CustomEditing a Service Search Search for Edit ServiceAuto Search and Store Selecting a SystemSearch for Search and Store Using the Close Call Feature Using the Close Call FeatureSetting Close Call Options Close CallSelect Mode Select Beep 10/15/30/45/60 secClose Call Hits Unlocking All Frequencies Search and Close Call OptionsManaging Locked-Out Frequencies Reviewing Locked Out FrequenciesSearching for Subaudible Tones Screening Out Broadcast SourcesSearch and Close Call Options Srch/CloCall Opt Max Auto Store Setting the Maximum Auto Store ValueSetting the Modulation Type Srch/CloCall Opt Set ModulationSrch/CloCall Opt Set Attenuator Setting AttenuationSetting Data Skip Srch/CloCall Opt Set Data SkipSrch/CloCall Opt Set Delay Time Setting the Delay TimeSetting the Search Frequency Step Srch/CloCall Opt Set Step Setting Air Band Step Setting Up Tone-Out Using Tone-OutSetting Tone-Out Standby Fire Tone-Out IntroductionUsing Tone-Out Page General Use Care and MaintenanceCleaning LocationBirdies Troubleshooting TroubleshootingError MemorySpecifications SpecificationsPage Optional Accessories Initial Setting of the Menus AppendixAppendix UHF Planning Collecting InformationPlanning System Name and Quick Key Group Name and Quick KeyFrequency-Alpha Tag-Priority Conventional System Worksheet Conventional System WorksheetDeclaration of Conformity Declaration of ConformiryUniden Corporation All rights reserved UBZZ01347ZZ0
Related manuals
Manual 94 pages 51.5 Kb