Uniden UBC3500XLT owner manual Setting Channel Priority, Setting Channel Alert, Set Alert

Page 53

Input the frequency, then press the scroll control. To change the frequency you entered, turn the scroll control to select Edit Frequency, then press the scroll control.

Setting Channel Priority

Menu

Program System

Select the system

Edit Group

Select the group

Edit Channel

Select the channel

Set Priority

This setting controls whether the scanner treats the channel as a priority channel while scanning. Select your setting, then press E.

On - when you turn on the Priority feature, the channel will be scanned every 2 seconds. P appears.

Off - the channel will not be treated with priority.

Note: The default setting is Off.

Setting Channel Alert

Menu

Program System

Select the system

Edit Group

Select the group

Edit Channel

Select the channel

Set Alert

Off - the scanner does not alert you to emergency transmissions.

Programming/Editing Optional Settings

53

Image 53
Contents UBC3500XLT OWNER’S Manual Earphone Warning PrecautionsContents Entering/Editing Conventional Channel Groups Contents Frequency MHz Modulation Step kHz Lower Edge Upper Edge IntroductionFrequency MHz Modulation Step kHz Lower Edge IntroductionGeneral Feature HighlightsFeature Highlights Search Priority Entering Text Using the Multifunction Scroll ControlAbout This Manual Edit Name How the Scanner’s Controls Are Represented in This ManualMenu Program System Page What is Searching? What is Scanning?Understanding Scanning Understanding the Scanner’s MemoryWhat is CTCSS/DCS? 023 025 026 031 032 036 043 047 Simplex Operation Conventional ScanningInformation On The Internet Where To Get More InformationRepeater Operation Included With Your Scanner Setting Up Your Scanner Setting Up Your ScannerUsing Internal Batteries Using Rechargeable Batteries Removing the Display Sticker Using AC PowerConnecting an Earphone/Headphone Connecting the AntennaConnecting an Extension Speaker Connecting an Optional AntennaLook At The Keypad Attaching the Belt ClipAttaching the Wrist Strap Hold Pri No/rev Look At The DisplayFunc Using Func Using MenuOnce. Volume Level and a Turning On the Scanner and Setting the SquelchBasic Operation Basic OperationSelecting Systems to Scan Scanning SystemsLocking/Unlocking Systems Selecting System Channel GroupsTemporarily Holding On a System Locking/Unlocking ChannelsHolding On a Channel Quick-Storing ChannelsToggling Channel Alpha Tags Quickly Recalling ChannelsMenu Item Submenu Using the MenuUsing the Menu Adjusting the Key Beep SettingsDisplaying System Information Locking/Unlocking the Keypad and ScrollUsing the Backlight Turning Power Save On or OffSettings Priority ScanAdjusting the Display Contrast Setting the Audio AGCConnecting Your Scanner to a Personal Computer Initializing the Scanner’s MemorySettings PC Control Using the Cloning OptionsWired Clone Wired CloningMaster scanner Clone Master Press Scan Key Slave scanner Clone Slave Press Scan KeyProgramming Conventional Systems Programming Radio SystemsProgramming Radio Systems Program System New SystemEdit Group New Group Entering/Editing Conventional Channel GroupsProgram System Edit Channel New Channel Entering/Editing Conventional ChannelsEdit Group Editing the System Name System-Level SettingsEditing the System Quick Key Edit Sys Option Set Quick KeySetting the System Hold Time Setting System LockoutProgramming/Editing Optional Settings Edit Sys Option Set LockoutSetting the Data Skip Setting the Channel Delay TimeEdit Sys Option Set Delay Time Edit Sys Option Set Data SkipDeleting Systems Group-Level SettingsCopying Systems Entering/Editing the Group NameSetting the Group Quick Key Setting Group Lockout Channel-Level SettingsDeleting Groups Editing the Channel NameInput Frequency Editing FrequenciesEdit Channel Set Alert Setting Channel PrioritySetting Channel Alert Set CTCSS/DCS Setting CTCSS/DCSSet Level Set Moduration Setting the Channel Frequency ModulationSet Attenuator Setting Channel AttenuationSetting Channel Lockout Copying/Pasting Channels Deleting ChannelsDelete Channel Copy ChannelEdit Channel Paste Channel Searching and Storing Service SearchChanging the step of Air Band Quick SearchSearch for Custom Search Custom SearchSearch for Edit Custom Editing a Custom Search RangeSearch for Edit Service Editing a Service SearchSelecting a System Auto Search and StoreSearch for Search and Store Using the Close Call Feature Using the Close Call FeatureClose Call Setting Close Call OptionsSelect Mode 10/15/30/45/60 sec Select BeepClose Call Hits Managing Locked-Out Frequencies Search and Close Call OptionsUnlocking All Frequencies Reviewing Locked Out FrequenciesSearch and Close Call Options Searching for Subaudible TonesScreening Out Broadcast Sources Setting the Modulation Type Setting the Maximum Auto Store ValueSrch/CloCall Opt Max Auto Store Srch/CloCall Opt Set ModulationSetting Data Skip Setting AttenuationSrch/CloCall Opt Set Attenuator Srch/CloCall Opt Set Data SkipSetting the Search Frequency Step Setting the Delay TimeSrch/CloCall Opt Set Delay Time Srch/CloCall Opt Set StepSetting Air Band Step Setting Tone-Out Standby Using Tone-OutSetting Up Tone-Out Fire Tone-Out IntroductionUsing Tone-Out Page Cleaning Care and MaintenanceGeneral Use LocationBirdies Troubleshooting TroubleshootingMemory ErrorSpecifications SpecificationsPage Optional Accessories Appendix Initial Setting of the MenusAppendix UHF Planning PlanningCollecting Information Group Name and Quick Key System Name and Quick KeyFrequency-Alpha Tag-Priority Conventional System Worksheet Conventional System WorksheetDeclaration of Conformiry Declaration of ConformityUniden Corporation All rights reserved UBZZ01347ZZ0