Uniden UBC785XLT manual 6RECORD

Page 25

UB343ZH_UBC785XLT_OM_0622 6/22/06 3:01 PM Page 21

Note: Through the System Menu you can set the radio to operate in Tone Search mode during Search as well. In this mode, the radio will automatically determine the active subaudible tone on any frequency received during the search.

6:RECORD

With this feature set to on, any frequency that is active during the search, can be recorded to an external tape recorder.

7:AUTO STORE

You can automatically store the active frequencies found during a search into the memory. You can select the bank to program. The audio will be muted.

2:SCAN OPTION

1:FREQUENCY

Allows you to program a frequency to a memory channel or edit the frequencyl already programmed. You can also set an alphanumeric text tag (alpha tag) for each programmed frequencies.

2:DELAY

You can set delay for the memory channel. The default delay is two seconds.

3:TONE DATA

You can set a CTCSS (analog) or DCS (digital) subaudible tone for a frequency. To do so you must have the SQ Mode in the System Menu set to Tone SQ. You can also program a subaudible tone easily by pressing the E key in Scan Hold mode after programming a frequency. This will bring up the Tone Data menu without having to navigate the Menu. By doing this you will receive all transmissions on the frequency, regardless of the subaudible tone, except the one which you have locked. Any transmissions with that tone will not be received.

4:BEEP ALERT

You can set a Beep Alert per channel to alert you when specific frequencies are active. For example, you may wish to be alerted anytime a mutual aid fire frequency is active. With Beep Alert, you will hear three beeps at the start of each transmission that you have flagged as such. You will also notice that as you scroll pass the flagged channel(s), you will hear three beeps.

5:ATTENUATOR

See 1: SEARCH OPTION/ 2:CHAIN SERACH/ 4:ATTENUATOR.

6:STEPS

Your UBCD785D is programmed with default step sizes for each frequency range (see page 1). Steps are important if you are interested in using the VFO to tune off from a frequency programmed into memory or if you wish to program a frequency that the default step size will not accept.

7:MODE

Default Auto receive modes are also programmed into memory. AM for aircraft for example. You can change the default settings on a per-channel basis with this Menu item.

21

Image 25
Contents A N N E R UB343ZHUBC785XLTOM0622 6/22/06 301 PM Contents UB343ZHUBC785XLTOM0622 6/22/06 301 PM Introduction 15kHz Offset UB343ZHUBC785XLTOM0622 6/22/06 301 PM VFO/SELECT Push Front and Rear ViewIcon Description UBC785XLT Shortcuts Press Menu Important Notice What is Searching? What is Scanning?Terminology Feature Highlights Information on the Internet Where to Obtain More InformationIncluded with Your Scanner Package Connecting an Antenna SetupMounting an Antenna Optional AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Applying Power Using Standard AC Power Desktop InstallationConnecting an External Speaker Connecting an EarphoneConnecting the Tape Recorder Connecting the Clone CableListening Safely Remember Basic Operation Setting the Squelch Turn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents 6RECORD Allows you to change the brightness of the display 9BANK TAG Programming Storing Frequencies into Channels in Menu Mode001 001 855.0000 FMC1000 010 512.0000 FM0000.0000 Transfer Frequencies 001 855.0000 NFM Alpha TAGStoring Alpha Tags Programming Tips Beep AlertAssigning the Beep Alert to a Channel To directly access a specific channel Scan Hold FeatureScanning BankSetting the Delay Mode for Frequency RF Attenuation Feature001 141.5000 FM Uniden Group a Lockout in Hold ModeChannel Lockout Restoring a Locked-out Channel Lockout in Scanning ModeRestoring All Locked-out Channels 005 512.0000 FM 010 1240.0000 FMPriority Scan Changing the Priority ChannelSearching Setting a Search RangeSrch 12.5k Srch 12.5k 1240.0000 FM Range 25cm Amateur Grp Search Hold FeatureStarting Chain Search Data SkipFrequency Skip Srch 12.5k 1240.0000 NFM Range C004Storing Search Frequencies 12--56 Squelch SQ Mode001 FM Bank Auto StoringFor Search mode, select 1SERVICE Option / Chain Search 001 FM DCS Bank 003003 FM DCS Uniden Group a 001 512.0000 FM BankUsing Aircraft Service Search Air Service SearchAir Service Search Skip Changing the stepRemote Interface PC Control ModeTo connect Scanner to PC To program your scannerStart Remote Mode and Change Transfer Speed Clone ModeSpeed 39600 bps 419200 bps PC Control ParameterTo connect the Scanner to Scanner Clone Master Unit Slave Unit Dimmer Additional FeaturesEnter Lock Key Beep OptionReceiving Mode Selection Reverse ModeFrequency and Channel Tuning with the VFO Control Channel Step SelectionCare and Maintenance Resetting the Scanner TroubleshootingSpecifications Glossary of Terms UB343ZHUBC785XLTOM0622 6/22/06 301 PM DCS Tone Code Ctcss Frequency List HzUBC785XLT Flow Charts Scan Option System Option Dimmer 1HIGH / 2MEDIUM / 3OFF Screen Mask Declaration of Conformity Uniden Corporation All rights reserved UBZZ01343ZZ0