Uniden UBC785XLT manual 12--56, FM Bank, Auto Storing, Squelch SQ Mode

Page 40

UB343ZH_UBC785XLT_OM_0622 6/22/06 3:01 PM Page 36

Auto Storing

The scanner automatically stores active frequencies if its Auto Store feature is turned ON. But the frequencies already stored can not be stored. To make use of this feature, set a search range first (see page 33). If you start this feature without setting a search range, NO LIMIT DATA appears on the display.

1.Press MENU.

2.Select 1:SERVICE OPTION / 2:CHAIN SEARCH / 7:AUTO STORE by rotating the VFO and pressing E.

3.Select 1:ON by rotating the VFO and pressing E.

Remember! You can also use or instead of rotating the

AUTO STORE

VFO. Also instead of pressing E, you can press the VFO

SELECT BANK

control.

12--56----

4. Select the bank number you want to store with the keypad.

 

The selected bank number appears on the display.

 

 

Note: If the selected bank has no free channels to store, CH

AUTO STORE

DATA FULL will appear on the display and you will

ERROR

hear a beep.

CH DATA FULL

 

6. Press SRCH to start auto storing.

 

7.When the selected bank has no free channel, the scanner stop auto storing and STORE END appears. If you want to stop auto storing on the way, press /HOLD.

Squelch (SQ) Mode

The scanner has the following SQ modes.

C 001

1245.8500 FM Bank 12--56----

AUTO STORE

Carrier SQ mode (default setting)

The scanner will stop on any active frequencies or squelch opening, regardless of whether any subaudible tone has been programmed on your scanner for the channel or search range.

Tone SQ mode

The scanner will stop on any active frequency for which you have not programmed any subaudible tone or whose subaudible tone is the same as the one you have programmed.

Tone Search mode

When the scanner stops on an active frequency, the scanner will begin searching the sub- audible tone used on the frequency one of which may also be in use. The scanner counts up through the CTCSS tones and instantly determines any possible DCS tone. See Page 51 for a listing of the tones that the UBC785XLT decodes.

Note: When Tone Search is active and the scanner finds the subaudible tone used on a frequency, CTCSS or DCS and subaudible tone flashes. You can press E to pro- gram that frequency with the found subaudible tone. When you change the mode to Tone SQ from Tone Search, you can confirm the frequency and subaudible tone has been programmed.

36

Image 40
Contents A N N E R UB343ZHUBC785XLTOM0622 6/22/06 301 PM Contents UB343ZHUBC785XLTOM0622 6/22/06 301 PM Introduction 15kHz Offset UB343ZHUBC785XLTOM0622 6/22/06 301 PM Front and Rear View VFO/SELECT PushIcon Description UBC785XLT Shortcuts Press Menu Important Notice What is Searching? What is Scanning?Terminology Feature Highlights Where to Obtain More Information Information on the InternetIncluded with Your Scanner Package Setup Connecting an AntennaMounting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Desktop Installation Applying Power Using Standard AC PowerConnecting an External Speaker Connecting an EarphoneConnecting the Clone Cable Connecting the Tape RecorderListening Safely RememberBasic Operation Setting the SquelchTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents 6RECORD Allows you to change the brightness of the display 9BANK TAG Storing Frequencies into Channels in Menu Mode Programming001 001 855.0000 FMC1000 010 512.0000 FM0000.0000 Transfer Frequencies 001 855.0000 NFM Alpha TAGStoring Alpha Tags Programming Tips Beep AlertAssigning the Beep Alert to a Channel Scan Hold Feature To directly access a specific channelScanning BankRF Attenuation Feature Setting the Delay Mode for Frequency001 141.5000 FM Uniden Group a Lockout in Hold ModeChannel Lockout Restoring a Locked-out Channel Lockout in Scanning ModeRestoring All Locked-out Channels 010 1240.0000 FM 005 512.0000 FMPriority Scan Changing the Priority Channel Searching Setting a Search Range Srch 12.5k Search Hold Feature Srch 12.5k 1240.0000 FM Range 25cm Amateur GrpStarting Chain Search Data SkipFrequency Skip Srch 12.5k 1240.0000 NFM Range C004Storing Search Frequencies Squelch SQ Mode 12--56001 FM Bank Auto StoringFor Search mode, select 1SERVICE Option / Chain Search 003 001 FM DCS Bank003 FM DCS Uniden Group a 001 512.0000 FM BankAir Service Search Using Aircraft Service SearchAir Service Search Skip Changing the stepPC Control Mode Remote InterfaceTo connect Scanner to PC To program your scannerClone Mode Start Remote Mode and Change Transfer SpeedSpeed 39600 bps 419200 bps PC Control ParameterTo connect the Scanner to Scanner Clone Master Unit Slave Unit Additional Features DimmerEnter Lock Key Beep OptionReverse Mode Receiving Mode SelectionFrequency and Channel Tuning with the VFO Control Channel Step SelectionCare and Maintenance Troubleshooting Resetting the ScannerSpecifications Glossary of Terms UB343ZHUBC785XLTOM0622 6/22/06 301 PM Ctcss Frequency List Hz DCS Tone CodeUBC785XLT Flow Charts Scan Option System Option Dimmer 1HIGH / 2MEDIUM / 3OFF Screen Mask Declaration of Conformity Uniden Corporation All rights reserved UBZZ01343ZZ0
Related manuals
Manual 60 pages 30.57 Kb