Uniden BC796D APC0 25 manual Storing Found Frequencies, Automatically Storing Frequencies

Page 33

To skip over a frequency, press L/O when the scanner is stopped on a frequency you want to skip.

Notes: • You can program up to 200 skip frequencies. The 201st skip frequency entered causes the first skipped frequency to unlock.

If all frequencies in the search range are set to skip, a beep sounds and it moves to Search Hold mode. To resume searching:

1) Unskip all skipped frequencies

—- OR —-

2) Select a different Search Frequency range.

To unskip all skipped frequencies, press and hold L/O for 2 seconds in Search Hold mode.

Storing Found Frequencies

If you find a frequency you want to save into a channel, simply press TRNFR when the scanner is stopped on that frequency. The scanner displays the lowest-numbered empty channel. Use the scroll bar to select the channel you want to save the frequency into, then press E.

Notes: • If you have already stored this frequency, the scanner displays WARNING DUPLICATE and the channel where the frequency is stored. To store the frequen- cy anyway, press E again.

After you store the frequency, the scanner resumes searching.

If all channels are used, the scanner defaults to the last-used channel prior to enter- ing the search mode.

Automatically Storing Frequencies

During searching, you can have the scanner automatically store active frequencies into a bank you choose.

1:SERVICE OPTION → :CHAIN SEARCH → 7:AUTO STORE → 1:ON

1.Press the numbers corresponding to the banks you want the scanner to store found frequencies into.

2.Press SRCH to start the auto-store operation.

3.Press /HOLD to stop auto-store. The scanner exits the auto-store mode.

Note: To ensure that you catch most active frequencies for the band, you should allow the auto-store operation to continue through at least a few complete sweeps of the band. Depending on the types of services, some occasionally active frequencies might not have activity for minutes or hours at a time.

27

Image 33
Contents Page Page Contents Programming Trunked Systems General Use Location Cleaning Repairs Birdies Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Conventional Scanning Understanding ScanningSimplex Operation Repeater OperationMotorola Trunking Trunked ScanningEdacs Trunking LTR Trunking Understanding Banks and ChannelsGetting More Information BC796D Front and Rear ViewIcon Description Display IconsIncluded With Your Scanner Connecting an Antenna Setting Up Your ScannerMounting an Antenna Optional AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Applying Power Using Standard AC Power Desktop InstallationConnecting an External Speaker Connecting an EarphoneConnecting the Tape Recorder Connecting the Clone CableListening Safely RememberSetting the Squelch Basic OperationTurning On the Scanner Manually Selecting a Channel Using the MenuScanning Programmed Channels Locking/Unlocking BanksRestoring All Locked Out Channels Locking/Unlocking ChannelsPriority Scanning Priority Plus ScanningControlling How Much Information Appears Dimmer Light SettingTurning the Key Beep On/Off Locking the Enter keyDisabling the APCO25 Card Setting Squelch ModeMuting All Audio Trunk Scanning OptionsMonitoring Talkgroup ID’s Scanning Only Stored Talkgroups ID ScanSelecting Talkgroup Lists to Scan Holding on a Single TalkgroupEdacs Blockout Unlocking All TalkgroupsEdacs Patch Tracking Setting Data Skip Setting Chain SearchSearching Holding on an Active FrequencyAutomatically Storing Frequencies Storing Found FrequenciesSetting Delay for All Search Ranges Setting Subaudible Tones for SearchingSearching for Subaudible Tones Attenuating All Search RangesSearching for Trunk Systems Setting a Search RangePage Service Search Skip Service SearchUsing Weather Search and Weather Alert Same Using Weather Alert SameSearching for a Weather Broadcast Testing the Weather Alert Bank Configuration Programming Bank InformationAssigning Bank Names Deleting Frequencies from Channels General ProgrammingTransferring Channel Information Entering Alpha InformationPage Select a Channel to Program Programming Conventional ChannelsEnter the Frequency Assigning a Text TagSetting the Subaudible Tone Option Setting the DelaySetting Beep Alert Setting the AttenuatorChanging the Frequency Step Setting Priority Channels Setting the Modulation ModeProgramming Trunked Systems Setting Trunking Delay Using I-Call Motorola and Edacs onlyTurning I-Call On and Off for ID Search Multi-Track Setting Priority Talkgroups Motorola and Edacs onlyTurning I-Call On for ID Scan Multi-Track Operational DetailsPage Using Control Channel Programming Programming Motorola SystemsProgramming Type 2/Digital 800 and 900 MHz Systems Programming Type2/Digital VHF and UHF Systems Programming Type I and IIi Hybrid Systems Toggling End Code Detect Toggling the Status BitSetting Edacs Emergency Alert Programming Edacs SystemsProgramming Edacs Channels Setting Edacs Decimal Mode Programming Apco 25 Systems Setting Apco 25 Sound QualityProgramming LTR Systems Programming Talkgroups Storing Known TalkgroupsStoring Found Talkgroups Deleting Stored Talkgroup ID’s Adding a Text Tag to an ID ListSeeing Talkgroup Activity Using the Remote Interface PC Control ModeCloning Scanner Settings Clone Master Unit Slave Unit Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code SVS Severe WX Reverse List BC796D Flow Charts Scan Option Conventional System Option Dimmer Uniden America Corporation One Year Limited WarrantyMemo Memo Memo