Uniden BC796D APC0 25 manual Programming Edacs Systems, Programming Edacs Channels

Page 55

Programming EDACS Systems

Follow the instructions in this section to program information for EDACS Wide, EDACS Narrow, and EDACS SCAT trunking systems. Note that to program these systems, in addition to knowing the system type and frequencies used, you must know the logical channel numbers (LCN) for the system’s frequencies. This information is usually provided with the frequency and other information. For more information refer to “Understanding Scanning.”

Programming EDACS Channels

1. Select the trunk type.

2:SCAN OPTION → 2:TRUNK → Select the bank → 1:TRUNK TYPE

1:ON

6:EDCS WIDE

Select for 9600 baud EDACS systems.

7:EDCS NARROW

Select for 4800 baud EDACS systems.

8:EDCS SCT.

Select for EDACS SCAT systems.

2.Program each trunk channel in LCN order (not frequency order). If you program this in the wrong order, the scanner will not go to the correct channel when scanning.

2:TRUNK CHANNEL ENTER CHANNEL No.

a.Enter the channel to program.

1:FREQUENCY

b.Enter the frequency then the alpha tag for the channel Repeat a and b for each channel in the system.

Note: EDACS SCAT systems use only one channel.

Once you complete channel programming, see “Programming Talkgroups.”

Setting EDACS Emergency Alert

When the emergency status is sent on an EDACS radio, you can have your scanner alert you to the transmission.

2:SCAN OPTION → 2:TRUNK → Select the bank → 0:EMERGENCY ALT

1:ON

The scanner beeps three times to alert you and flashes EMERGENCY during emergency transmissions.

2:OFF

The scanner does not handle emergency transmissions any differently than other transmissions.

49

Image 55
Contents Page Page Contents Programming Trunked Systems General Use Location Cleaning Repairs Birdies Page FCC Wants You To Know Scanning Legally Introduction Page Using this Manual Repeater Operation Understanding ScanningConventional Scanning Simplex OperationMotorola Trunking Trunked ScanningEdacs Trunking LTR Trunking Understanding Banks and ChannelsGetting More Information BC796D Front and Rear ViewIcon Description Display IconsIncluded With Your Scanner Optional Antenna Setting Up Your ScannerConnecting an Antenna Mounting an AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Connecting an Earphone Desktop InstallationApplying Power Using Standard AC Power Connecting an External SpeakerRemember Connecting the Clone CableConnecting the Tape Recorder Listening SafelyBasic Operation Setting the SquelchTurning On the Scanner Locking/Unlocking Banks Using the MenuManually Selecting a Channel Scanning Programmed ChannelsPriority Plus Scanning Locking/Unlocking ChannelsRestoring All Locked Out Channels Priority ScanningLocking the Enter key Dimmer Light SettingControlling How Much Information Appears Turning the Key Beep On/OffTrunk Scanning Options Setting Squelch ModeDisabling the APCO25 Card Muting All AudioHolding on a Single Talkgroup Scanning Only Stored Talkgroups ID ScanMonitoring Talkgroup ID’s Selecting Talkgroup Lists to ScanUnlocking All Talkgroups Edacs BlockoutEdacs Patch Tracking Holding on an Active Frequency Setting Chain SearchSetting Data Skip SearchingAutomatically Storing Frequencies Storing Found FrequenciesAttenuating All Search Ranges Setting Subaudible Tones for SearchingSetting Delay for All Search Ranges Searching for Subaudible TonesSearching for Trunk Systems Setting a Search RangePage Service Search Skip Service SearchUsing Weather Alert Same Using Weather Search and Weather Alert SameSearching for a Weather Broadcast Testing the Weather Alert Programming Bank Information Bank ConfigurationAssigning Bank Names Entering Alpha Information General ProgrammingDeleting Frequencies from Channels Transferring Channel InformationPage Assigning a Text Tag Programming Conventional ChannelsSelect a Channel to Program Enter the FrequencySetting the Subaudible Tone Option Setting the DelaySetting the Attenuator Setting Beep AlertChanging the Frequency Step Setting Priority Channels Setting the Modulation ModeProgramming Trunked Systems Using I-Call Motorola and Edacs only Setting Trunking DelayTurning I-Call On and Off for ID Search Multi-Track Operational Details Setting Priority Talkgroups Motorola and Edacs onlyMulti-Track Turning I-Call On for ID ScanPage Programming Motorola Systems Using Control Channel ProgrammingProgramming Type 2/Digital 800 and 900 MHz Systems Programming Type2/Digital VHF and UHF Systems Programming Type I and IIi Hybrid Systems Toggling End Code Detect Toggling the Status BitProgramming Edacs Systems Setting Edacs Emergency AlertProgramming Edacs Channels Setting Edacs Decimal Mode Programming Apco 25 Systems Setting Apco 25 Sound QualityProgramming LTR Systems Storing Known Talkgroups Programming TalkgroupsStoring Found Talkgroups Adding a Text Tag to an ID List Deleting Stored Talkgroup ID’sSeeing Talkgroup Activity PC Control Mode Using the Remote InterfaceCloning Scanner Settings Clone Master Unit Slave Unit Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code SVS Severe WX Reverse List BC796D Flow Charts Scan Option Conventional System Option Dimmer Uniden America Corporation One Year Limited WarrantyMemo Memo Memo