Whistler 200/400 WATT Additional Features, Automatic Shut Down & Related Safety Features, Red Led

Page 8

OPERATION

within the appliance or equipment being operated. If the fuse(s) does blow, turn off and disconnect the appliance or equipment from the inverter immediately, repair the related problem and replace the fuse(s). The internal fuses are replaceable, however, only electronically knowledgeable people should attempt fuse replacement

Note:

Make certain to correct the source of the overload which caused the blown fuse before turning your inverter back ON (l).

The Power Source.

When the engine is off, most batteries will provide an ample power supply to the inverter for one to two hours. The actual length of time is a function of several variables including the age and condition of the battery and the power demand being placed on it by the equipment being operated with the inverter.

If you are using the inverter while the engine is off, we recommend you start the engine every hour and let it run for at least 10 minutes to recharge the battery. We also recom- mend that the device plugged into the inverter be turned off before turning over the engine.

Although it is not necessary to disconnect the inverter when turning over the engine, the inverter may momentarily cease operation as the battery voltage decreases. When the invert- er is not supplying power, and turned on, it draws very low amperage from the battery (<0.40 A ).

ADDITIONAL FEATURES

Automatic Shut Down & Related Safety Features.

Each inverter has an unique LED indicator warning light sys- tem which operates in conjunction with the automatic shut down feature. These indicator lights operate as follows:

GREEN LED:

System ready.

RED LED:

System overload/automatic shut down.

Your inverter will shut down automatically when any of the following problems occur:

1.The power input from the battery drops below 10 volts.

2.The power input from the battery exceeds 15 volts.

3.The continuous draw of the appliance or equipment being operated exceeds the design parameters of the inverter.

The inverters are also equipped with the following additional safety features:

1.Thermal Cut Off:

Automatic shut down if internal temperature exceeds safe design parameters.

12

13

Image 8
Contents 200/400 Watt Introduction Whistler GROUP, INCTable of Contents Whistler FeaturesGetting Started Important InformationInverter Basics Inverter Basics Operation Operation Additional Features Automatic Shut Down & Related Safety FeaturesGreen LED System readyCare and Maintenance Low Battery Voltage Alarm/Shutdown ProtectionTrue sine wave typical of home AC outlet Operating PrinciplesFor You Technical Types Basic Operating Principles Operation Summary Troubleshooting ProblemWhistler 400 Watt Inverter Specifications SpecificationsWhistler 200 Watt Inverter Specifications Warranty Warranty