Z Microsystems SL manual Command Console Serial Control ICD, Command Structure

Page 47

APPENDIX

COMMAND CONSOLE SERIAL CONTROL ICD

The following serial port property settings must be in place in order for the host to have communication with the display.

SPEED

19,200 BPS

DATA BITS

8

PARITY

None

STOP BITS

1

FLOW CONTROL None

The serial control ICD commands are presented here for the user’s knowledge. The commands are written and controlled by Z Microsystems and are not intended for the customer to use. Any improper use of the commands may place the panel in an unstable state and may degrade the image quality, thereby voiding the warranty by the user.

Command Structure

The command structure for the majority of the commands for the display follow the follow- ing structure:

Z<space>U<space><command><space><argument>

where...

“command” = the ascii string that represents the command “argument” = the optional argument to the command “space” = ascii character 0x20

The command structure must be succeeded by a carriage return (0x0D).

The controller returns a string of tildes (‘~’) indicating that the command has been ac- cepted and processed. Some of the commands return other information which will be specified on a per command basis.

Unless otherwise specified the command strings examined in this document must be placed in the above structure when being sent to the controller.

The commands will be broken down by the image on which it operates (i.e. the main im- age). There may be overlap between the different images and the commands that work on them.

Main Image—Standard Command Structure

The following commands operate on the main image.

PAA

Description

PAA has the controller perform its auto adjust algorithm. This often helps the main image properly position itself if an uncommon image stream is provided to the display.

47

Doc# 27-0032UM Rev A Issued 07/05

Image 47
Contents Command Console FCC Information RegulatoryTable of Contents About Manual Safety PrecautionsIntroduction Product Description Shipment Contents InstallationHardware Installation Install Rails Installation Install Console Secure the left side also, as shown above Locks Description Setup Console Installation Close Console Cable Connections Power UPOperations Channels Display Panel ControlsDisplay Panel Setup Onscreen Menus Main Screen Picture AdjustMain Screen Color Balance Main Screen Graphics ModeMain Screen Configuration Menu TimeoutReset Default Settings Main Screen InformationKVM Control see KVM on screen on previous Softmenus Monitor SoftMenus Monitor Screen Factory Default and Auto Adjust ButtonsEdit Menu BARFile Ctrl + B HOT KeysTools HelpKVM Control Maintaining the Command Console Cleaning the Command Console MaintenanceNo Main Display Image TroubleshootingTroubleshooting the Command Console Display Image Appears Fuzzy Power Light Does Not IlluminateDisplay Image Has Vertical Bars Mechanical Outline for Command Console Schematics17.853 Back of Rack Front of Rack 1st Locking Position Front of Rack Replacing Parts ReplacementsAppendix Specifications for Command ConsoleReliability MIL-STD-167Warranties Standard WarrantyExtended Warranty Preferred Warranty Airspare Warranty On-Site Service Disclaimer Customer Support Customer Feedback ZspaceUspacecommandspaceargument Command Console Serial Control ICDCommand Structure Main Image-Standard Command Structure=mode~~~ PBBPDS PVP Non-Standard Command StructureMicrosystems, Inc