NEC 2400 ipx system manual Contents

Page 55

OPERATION TESTS AFTER INSTALLATION

1.Test of IP-LINK lamp on IPTRK circuit card: Note

Note: H.323 Handler (PA-8IPTB-A).

a.)

See if the IP-LINK lamp on the IPTRK circuit card Note is lighting green.

 

 

 

 

This lamp will light if the circuit card is physically connected to the IP

 

 

 

 

 

 

 

 

network.

ATTENTION

 

 

Contents

Note: H.323 Handler (PA-8IPTB-A).

Static Sensitive

Handling

 

 

Precautions Required

b.)

When the IP-LINK lamp is OFF, make sure that the Ethernet cable is securely

 

 

 

 

connected to the IPCON connector. Make sure that neither the Ethernet cable nor the router are

 

faulty. If necessary, replace the Ethernet cable.

 

 

 

2.Test of SUBOPE1 lamp on IPTRK circuit card Note:

Note: H.323 Handler (PA-8IPTB-A).

a.) See if the SUBOPE1 lamp on the IPTRK circuit card Note is lighting green. This lamp will light when the appropriate data has been assigned on the Gate Keeper (GK) side.

Note: H.323 Handler (PA-8IPTB-A).

b.) When the SUBOPE1 lamp is OFF, make sure that the related office data is correctly assigned on both the PBX side and the Gate Keeper (GK) side.

3.Test of IP-LRR lamp on IPTRK circuit card: Note

Note: H.323 Handler (PA-8IPTB-A).

a.) See if the IP-LRR lamp on the IPTRK circuit card Note is lighting green. This lamp will light if the IP network is available for connection establishment.

Note: H.323 Handler (PA-8IPTB-A).

b.) When the IP-LRR lamp is OFF, make sure that the related office data was correctly assigned. Make sure that each IP address assigned on the AGIP command is correct.

4.Test of Speech Conditions with Distant Node:

a.) Perform the connection test to see if speech can be made with the counterparts of the connected node.

b.) If any test result is abnormal, make sure that the related office data was assigned correctly.

5.Test of System Messages:

a.) When an IPTRK circuit card Note is installed, the following messages may be created:

Note: H.323 Handler (PA-8IPTB-A).

For CCIS Networking via IP [C-163]:

33-R IP CARD WARNING

33-S IP CARD FAILURE

33-T IP CARD RECOVERY

33-U H.323 INFORMATION NOTICE

b.) When any of the messages above are created, make sure that the Ethernet cable is securely connected to the IPCON connector (on the IPTRK circuit card), or perform the continuity test of the cable (voltage and resistance measurement), using a voltmeter. Otherwise, replace the IPTRK circuit card or H.323 Handler.

CHAPTER 4

NDA-24318

Page 48

Issue 1

Image 55
Contents November IssueLiability Disclaimer NEAX2400 IPX NEAX2400 IPX Table of ContentsList of Figures List of Tables This page is for your notes General IntroductionNEAX2400 IPX Service Features to be ProvidedBlock Diagram Ccis Networking via IP To Iptrk Block Diagram Fccs Networking via IP Circuit Card Explanations HOW to Follow this Manual and Related Reference ManualsCircuit Card Explanations PA-8IPTB Circuit Card Mounting Locations Port Assignment for PA-8IPTB Circuit Card Lamp indication meanings are shown below Meaning of each switch on this card is shown below OFF SW20 Dynamic Controlling PAD no Pattern Send Receive PA-8IPTB Attachment of Sub Board PZ-8VCTB onto Iptrk Circuit Card PZ-8VCTB Sub Board Ccis Networking VIA IP C-163 Office Data ProgrammingRequired Hardware Required Hardware Point-to-Multipoint Connection Service Conditions Feature Feature Name Condition Number Data Programming Port Assignment of Bch for Ccis Tie Line Acsc Iptrk Ccis Node Node B Node C Overview of Fccs Networking via IP F-36 Fccs Networking VIA IP F-36Example Required Hardware for Fccs Networking via IP F-36 Node a Node B Alternate Routing OK Symbols Bch Speech Iptrk firmware ASYDL, SYS 1, Index 527, b6 Example Data Assignment Acrd 10 Example Data Assignment Actk Fchn = 1 Fchen = 12 Example Assignment of Destination IP and Next IP Aeth Step Iptrk Fccs Data Assignment at Node a Fccs Routing Example Data Sheets 16 Fccs Networking via IP F-36 Example Data Sheet NEAX2400 IPX FPC DTI FCH Fchn Fchn FPC=3, FCHN=3, CRT=70, DSTIP=0.0.0.0, NEXTIP=0.0.0.0 Note Ccis Networking VIA IP C-163/VOICE Over IP H.323 Operation Tests After InstallationContents Test of OPE lamp on Iptrk circuit card Fccs Failure