Advanced PIP

1

2

3

4

Press to display the Setup menu.

Press to select “OSD Language”.

Press and hold until the Options menu is displayed. Press to select Advanced PIP.

 

 

 

 

Options

 

1/3

5

Press to adjust the menu.

 

Off-timer function

Enable

 

Off : Sets normal two screen display mode

Onscreen display

On

 

 

 

 

 

 

 

(see page 22).

 

 

Initial INPUT

Off

 

 

 

 

Initial VOL level

Off

0

 

On : Sets Advanced PIP mode.

 

 

 

Maximum VOL level

Off

0

 

Press to confirm.

 

 

INPUT lock

Off

 

 

 

 

Studio W/B

Off

 

 

 

 

 

 

 

 

 

 

Advanced PIP

Off

 

6

 

 

 

Display size

Off

 

Press to exit from

One screen

Advanced PIP

 

 

(When Advanced PIP is On)

Options menu.

 

 

 

 

 

 

 

 

 

 

 

7

Press repeatedly.

Sub screen

Main screen

 

 

 

Each time pressing this

 

 

 

 

 

button main picture and

 

 

 

 

 

sub picture will

be

 

 

 

 

Note:

displayed as above.

 

 

 

 

 

 

 

 

 

 

 

Notes:To use , , , buttons for the screen operations, follow the procedures in the previous page.

• Advanced PIP corresponding signal

Sub screen

Main screen

NTSC, PAL, SECAM (tuner, video)

640x480@60Hz, 852x480@60Hz, 1024x768@60Hz,

525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i,

1366x768@60Hz (RGB, DVI, HDMI)

1125/50i, 1250/50i (Component Video, RGB, DVI, SDI, HDMI)

1280x768@60Hz (DVI)

Sound output is from the picture which is selected in Audio OUT (PIP) (See page 26).

In 2 screen display, the same input mode cannot be selected for the main picture and sub picture.

The main picture and sub picture are processed by different circuits, resulting in a slight difference in the clarity of the pictures. There may also be a difference in the picture quality of the sub picture depending on the type of signals displayed on the main picture and depending on the 2-picture display mode.

Due to the small dimensions of the sub pictures, these sub pictures cannot be shown in detail.

Computer screen picture is displayed in a simplified format, and it may not be possible to discern details on them satisfactorily.

Following combinations of two analog signals cannot be displayed simultaneously;

Component - Component, Component - PC (RGB), PC (RGB) - Component, PC (RGB) - PC (RGB)

Following signals are not applicable to this menu.

1125 / 50p • 60p, 1152 × 864 @60 Hz, 1400 × 1050 @60 Hz, 1600 × 1200 @60Hz, 1920 × 1200 @60 Hz

Refer to each board's operating instruction for DVI, SDI, HDMI's corresponding signals.

23

Image 23
Contents Model No. TH-50PF9UK High Definition Plasma DisplayOperating Instructions EnglishRisk of Electric Shock Do not Open Important Safety Instructions Table of Contents Trademark Credits FCC CautionCanadian Notice When using the Plasma Display Safety PrecautionsAC Power Supply Cord MaintenanceSafety Precautions / Maintenance SetupRemote Control Batteries AccessoriesAccessories Supplied DVI-D COMPONENT/RGB ConnectionsSpeakers AC cord fixingConnections Signal Names for Mini D-sub 15P ConnectorPC Input Terminals connection Basic format for control data CommandSerial Terminals connection Communication parametersDVI-D connection Component / RGB connection & RGB signal R, G, BDVI-D Input Connector Signal NameConnecting the plug to the Wall Outlet Power on / OFFConnecting the AC cord plug to the Plasma Display OFF Basic ControlsBasic Controls On-Screen Menu Displays Advanced SettingsOn-Screen Menu Displays Time / Power OFF TimeOn Time / Power OFF INPUT1 INPUT2 INPUT3 PC Selecting the input signalInitial selections Selecting the On-Screen Menu LanguageNormal Full Aspect ControlsNormal Zoom Full Pixel Mode Adjusting POS. /SIZEPOS / V-SIZE / DOT Clock / Clock Phase Size Adjusting POS. /SIZEClock Phase POSMulti PIP Sub screen Main screen Advanced PIPCinema Picture AdjustmentsStandard DynamicPicture Adjustments Advanced SettingsMute Sound AdjustmentReturn to normal display quit Digital Zoom Digital ZoomDisplay the Operation Guide Select the magnification required for the enlarged displayPress to select Set Present Time SetupPress to set up Present Time of DAY Press to select Power on Function SET UP TimerDisplay the SET UP Timer Screen Press to select Power on Time / Power OFF TimeNegative / Scroll selection Mode selectionStart setting Screensaver For preventing after-imagesScreensaver For preventing after-images Setup of Screensaver TimePress to display the SET UP menu Reduces screen after-imagePress to exit from Screensaver Side BAR AdjustOFF Dark MID Bright Addition sign Selected Input Reduces power consumptionCustomizing the Input labels Press to select on or OFF SET UP for Multi DisplayHow to setup Multi Display Group of 4 2 × Group of 9 3 × Group of 16 4 ×Display Number locations for each arrangement Examples SET UP for Multi DisplayPress to select Seam Hides Video Press to select OFF, onID Cancellation Seam Hides Video SettingID Remote Control Function ID remote control button operationComponent RGB SET UP for Input SignalsComponent / RGB in Select 3D Y/C Filter For Ntsc AV imagesColor System SET UP for Input SignalsColor System / Panasonic Auto Pulldown / Video NRDisplays the H Horizontal / V Vertical frequencies Setting RGB sync signalSync FREQ. kHz / V-FREQ. HzFunction Options AdjustmentsOff Initial VOL Sets normal volume Level Options AdjustmentsMenu & Enter NormalizationShipping condition Plasma Display panel TroubleshootingDVI-D DVI-D/COMPONENT/RGB/PC input signalsTH-50PF9UK SpecificationsLimits and Exclusions Panasonic Canada Inc Customer’s RecordPanasonic Broadcast & Television Systems Company Executive Office