Panasonic TH-50PF9UK operating instructions Specifications

Page 46

Specifications

 

 

 

TH-50PF9UK

Power Source

 

120 V AC, 50/60 Hz

Power Consumption

 

 

 

 

Power on

 

650 W

 

Stand-by condition

 

Save OFF 1.0 W, Save ON 0.8 W

 

Power off condition

 

0.1 W

Plasma Display panel

 

Drive method : AC type 50-inch,

 

 

 

16:9 aspect ratio

Screen size

 

43.5” (1,106 mm) (W) × 24.5” (622 mm) (H)

 

 

 

× 50” (1,269 mm) (diagonal)

 

(No.of pixels)

 

2,073,600 (1,920 (W) × 1,080 (H))

 

 

 

[5,760 × 1,080 dots]

Operating condition

 

 

 

 

Temperature

 

32 °F - 104 °F (0 °C - 40 °C)

 

Humidity

 

20 % - 80 %

Applicable signals

 

 

 

 

Color System

NTSC, PAL, PAL60, SECAM, Modified NTSC

 

 

Scanning format

525 (480) / 60i · 60p, 625 (575) / 50i · 50p, 750 (720) / 60p · 50p, 1125 (1080) / 60i · 60p · 50i · 50p

 

 

·24p · 25p · 30p · 24sF ···· SMPTE274M, 1250 (1080) / 50i

 

PC signals

 

VGA, SVGA, XGA, SXGA,

 

 

 

UXGA ···· (compressed)

 

 

 

Horizontal scanning frequency 15 - 110 kHz

 

 

 

Vertical scanning frequency 48 - 120 Hz

Connection terminals

 

 

 

 

DVI-D

Video Input

 

DVI-D 24 Pin x 1

 

 

 

 

compliance with DVI Revision 1.0

 

 

 

 

* Refer to page 12 for applicable signals

 

 

Audio Input

 

Stereo mini jack (M3) x 1

 

 

 

 

0.5 Vrms

 

 

Content Protection

 

Compatible with HDCP 1.1

 

COMPONENT/RGB

Y/G (BNC)

 

Y or G with/sync 1.0 Vp-p (75 Ω)

 

 

PB/B (BNC), PR/R (BNC)

 

0.7 Vp-p (75 Ω)

 

 

AUDIO IN (RCA PIN JACK × 2)

0.5 Vrms

 

PC

(HIGH-DENSITY MINI D-SUB 15PIN)

Y or G with/sync 1.0 Vp-p (75 Ω)

 

 

 

B/PB/CB :

Y or G without/sync 0.7 Vp-p (75 Ω)

 

 

 

0.7 Vp-p (75 Ω)

 

 

 

R/PR/CR :

0.7 Vp-p (75 Ω)

 

 

VBS(use HD port)

HD/VD:

1.0 - 5.0 Vp-p (high impedance)

 

 

 

with/picture 1.0 Vp-p (high impedance)

 

 

AUDIO IN (M3 JACK)

 

without/picture 0.3 Vp-p (high impedance)

 

 

 

0.5 Vrms

 

SERIAL

EXTERNAL CONTROL TERMINAL (D-SUB 9PIN)

RS-232C COMPATIBLE

 

SPEAKERS (6 Ω)

 

16 W [8 W + 8 W] (10 % THD)

Accessories Supplied

 

 

 

 

Remote Control Transmitter

 

EUR7636070R

 

Batteries

 

2 × AA Size

 

Fixing bands

 

(TMME203 or TMME187) × 2

Dimensions (W × H × D)

47.6” (1,210 mm) × 28.5” (724 mm) × 3.7” (95 mm)

 

(excluding handle portion)

 

 

 

Mass (weight)

 

 

 

 

main unit only

 

approx. 92.6 lbs

 

with speakers

 

approx. 101.4 lbs

Note:

Design and specifications are subject to change without notice. Mass and dimensions shown are approximate.

46

Image 46
Contents English High Definition Plasma DisplayOperating Instructions Model No. TH-50PF9UKRisk of Electric Shock Do not Open Important Safety Instructions Table of Contents Canadian Notice FCC CautionTrademark Credits Safety Precautions When using the Plasma DisplaySetup MaintenanceSafety Precautions / Maintenance AC Power Supply CordAccessories Supplied AccessoriesRemote Control Batteries AC cord fixing ConnectionsSpeakers DVI-D COMPONENT/RGBPC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorConnections Communication parameters CommandSerial Terminals connection Basic format for control dataSignal Name Component / RGB connection & RGB signal R, G, BDVI-D Input Connector DVI-D connectionConnecting the AC cord plug to the Plasma Display Power on / OFFConnecting the plug to the Wall Outlet Basic Controls OFFBasic Controls Advanced Settings On-Screen Menu DisplaysOn Time / Power OFF Time / Power OFF TimeOn-Screen Menu Displays Selecting the On-Screen Menu Language Selecting the input signalInitial selections INPUT1 INPUT2 INPUT3 PCNormal Zoom Full Aspect ControlsNormal Full POS / V-SIZE / DOT Clock / Clock Phase Adjusting POS. /SIZEPixel Mode POS Adjusting POS. /SIZEClock Phase SizeMulti PIP Advanced PIP Sub screen Main screenDynamic Picture AdjustmentsStandard CinemaAdvanced Settings Picture AdjustmentsSound Adjustment MuteSelect the magnification required for the enlarged display Digital ZoomDisplay the Operation Guide Return to normal display quit Digital ZoomPress to set up Present Time of DAY Present Time SetupPress to select Set Power on Time / Power OFF Time SET UP TimerDisplay the SET UP Timer Screen Press to select Press to select Power on FunctionScreensaver For preventing after-images Mode selectionStart setting Negative / Scroll selectionReduces screen after-image Setup of Screensaver TimePress to display the SET UP menu Screensaver For preventing after-imagesOFF Dark MID Bright Side BAR AdjustPress to exit from Screensaver Customizing the Input labels Reduces power consumptionAddition sign Selected Input Group of 4 2 × Group of 9 3 × Group of 16 4 × SET UP for Multi DisplayHow to setup Multi Display Press to select on or OFFPress to select OFF, on SET UP for Multi DisplayPress to select Seam Hides Video Display Number locations for each arrangement ExamplesID remote control button operation Seam Hides Video SettingID Remote Control Function ID Cancellation3D Y/C Filter For Ntsc AV images SET UP for Input SignalsComponent / RGB in Select Component RGBPulldown / Video NR SET UP for Input SignalsColor System / Panasonic Auto Color SystemFREQ. kHz / V-FREQ. Hz Setting RGB sync signalSync Displays the H Horizontal / V Vertical frequenciesOptions Adjustments FunctionOptions Adjustments Off Initial VOL Sets normal volume LevelNormalization Menu & EnterShipping condition Troubleshooting Plasma Display panelDVI-D/COMPONENT/RGB/PC input signals DVI-DSpecifications TH-50PF9UKLimits and Exclusions Executive Office Customer’s RecordPanasonic Broadcast & Television Systems Company Panasonic Canada Inc