General Information
Technical data about this product
Monitor station
Power supply: | 24 V DC |
Current consumption: | Standby: Approximately 37 mA |
| At operation: Approximately 420 mA |
Dimensions: | Approximately height 136 mm x width 136 mm x depth 32 mm |
| (53/8" x 53/8" x 11/4") |
Mass (Weight): | Approximately 350 g (0.77 lb.) |
Operating environment: | 0 °C to 40 °C (32 °F to 104 °F), Up to 90% RH |
| (Relative Humidity) non condensing |
Installation method: | Wall mount (Wall mount bracket included) |
External material: | Flame retardant ABS resin (panel: acrylic resin) |
Note:
LTo connect to a door opener, make sure the door opener is:
–Normal open (Low active)
–Less than 30 V AC (1 A), 24 V DC (1 A)
AC adaptor (Part number: PFAP1014)
Power supply: | 100 V – 240 V AC, 50 Hz / 60 Hz |
Output voltage: | 24 V DC |
Output current | 2 A |
Dimensions: | Approximately height 120 mm x width 60 mm x depth 35 mm |
| (43/4" x 23/8" x 13/8") |
Mass (Weight): | Approximately 310 g (0.68 lb.) |
Operating environment: | 0 °C to 40 °C (32 °F to 104 °F), Up to 90% RH |
| (Relative Humidity) non condensing |
Note:
LDesign and specifications are subject to change without notice.
LThe pictures and illustrations in these instructions may vary slightly from the actual product.
30