PROJECTOR SETUP menu

DATE AND TIME

You can set the time zone and correct the time and date of internal clock.

TIME ZONE

Select the current located time zone.

 

 

 

Adjust YEAR, MONTH, DAY, HOUR

ADJUST CLOCK

and MINUTE by pressing I H, then

select APPLY and press the ENTER

 

 

button.

 

 

SAVE ALL USERS DATA

You can save various setting values as a backup to the internal memory of the projector.

1. Press the ENTER button.

The SECURITY PASSWORD will be asked to perform.

2.Perform the SECURITY PASSWORD.

The confirmation screen will be displayed. See “SECURITY PASSWORD” on page 35.

3.Press I to select OK, then press the ENTER button.

NOTE:

E-mail settings of NETWORK that is controlled by web browser, and the image data for LOGO1 in BACK COLOR and STARTUP LOGO will not be saved.

INITIALIZE

You can reset the settings to the factory defaults by the selected mode.

1.Select the required mode to initialise.

2.Press the ENTER button.

3.Perform the SECURITY PASSWORD.

The confirmation screen will be displayed. See “SECURITY PASSWORD” on page 35.

4.Press I to select OK, then press the ENTER button.

When initialising by ALL USER DATA, switch off the power and restart the projector.

 

All setting values including registered

 

signals in SIGNAL LIST, e-mail

ALL USER DATA

settings of NETWORK, and registered

image data for LOGO1 in BACK

 

 

COLOR and STARTUP LOGO will

 

return to factory settings.

 

All registered signal settings in

ENTRY SIGNAL

SIGNAL LIST will return to factory

 

settings.

 

All setting values in NETWORK

NETWORK/E-MAIL

including e-mail settings will return to

 

factory settings.

 

The registered image data for LOGO1

LOGO IMAGE

in BACK COLOR and STARTUP

 

LOGO will return to factory settings.

LOAD ALL USERS DATA

You can load the saved data in SAVE ALL USER DATA. 1. Press the ENTER button.

The SECURITY PASSWORD will be asked to perform.

2.Perform the SECURITY PASSWORD.

The confirmation screen will be displayed. See “SECURITY PASSWORD” on page 35.

3.Press I to select OK, then press the ENTER button.

4.The projector returns to the standby mode to reflect the saved data.

SERVICE PASSWORD

SERVICE PASSWORD is for a service person.

Settings

ENGLISH - 31

Image 31
Contents PT-DZ6700 PT-DW6300 PT-D6000 PT-D5000 Contents Height of the projection area Setting upScreen size and throw distance Projection distancePT-DZ6710/PT-DZ6700 Setting up Projection distance by projection lensPT-DW6300 Setting upThrough ratio Fixed PT-D6000/PT-D5000PT-DW6300 PT-DZ6710/PT-DZ6700PT-D6000/PT-D5000 Side view Geometric adjustmentScreen ScreenFront leg adjusters and throwing angle Connections Pin assignments and signal namesBefore connection to the projector Connections Connecting example ComputersConnecting example AV equipment Connecting with Video IN/S-VIDEOMain menu and Sub-menu Menu NavigationTest Pattern Signal List Projector SetupMenu Navigation Display OptionSecurity Displaying the main menu Adjusting with the bar scale itemsOperating procedure Navigating through the menuPicture menu Sharpness White GainNoise Reduction System Daylight ViewAspect ratio options Position menuShift AspectZoom Clock PhaseGeometry Vertical Keystone Lens Throw Ratio Position menuKeystone Blanking Input ResolutionSetting range Digital Cinema RealitySelecting gamma level Adjusting with colour markersAdjusting Edge Blending Edge BlendingProjection range Adjusting brightness around borderline of the image areaBright adjustment right Marker Raster PositionDisplay Option menu ON-SCREEN Display Auto SetupDVI-D SDISide by Side Back ColorStartup Logo FreezeProjector ID Projector Setup menuInstallation High Altitude ModeLamp Select Lamp PowerStandby Mode REMOTE2 ModeFunction Button Filter Counter ResetNo Signal SHUT-OFF StatusInitialize Service PasswordDate and Time Save ALL Users DataSelect Test Pattern menu Test PatternPress I H to select the required test pattern Managing the list and the registered data Signal List and SUB Memory ListManaging the sub memory list Signal ListSecurity menu Security Password ChangeSecurity Password Display SettingMenu Lock Menu Lock PasswordControl Device Setup Remote ControllerNetwork Status Network SetupNetwork menu Network ControlNetwork connection Technical InformationLAN terminal Technical Information Accessing with the web browserChange password Administrator modeUser account User modeBasic control Detail controlAuthentication set up Detailed set upNetwork config Adjust clockMail report sample Error report sample Mail set upClick Detail Error informationStatus Projector statusPJLink security authorization Control commandsPJLinkTMprotocol Connection Pin assignments and signal namesCommunication settings Serial terminalTechnical Information Basic format Cable specificationsContact Remote 2 in terminalPin assignments and control OtherMovie signals Side by Side function signal combination tableRestoring the Menu Lock Password to default Side by Side function signal combination tableTrademark acknowledgements Index Combination table Index