Technical Information
PJLinkTMprotocol
The network function of the projector supports PJLink™ class 1, and the PJLink™ protocol can be used to perform projector setting and projector status query operations from a computer.
Control commands
Command | Control details |
|
| Parameters/Notes |
| |||
POWR | Power supply control | 0 | = | Standby | 1 | = | Power ON | |
POWR ? | Power supply status query | 0 | = | Standby | 1 | = | Power ON | |
2 | = | 2 | = | |||||
|
| |||||||
INPT | Input selection | 11 | = | RGB1 | 12 | = | RGB2 | |
|
| 21 | = | VIDEO | 22 | = | ||
INPT ? | Input selection query | |||||||
31 | = |
| 32 | = | SDI | |||
AVMT | Shutter control | 30 | = | Shutter mode off (picture mute cancelled) | ||||
AVMT ? | Shutter mode query | 31 | = | Shutter mode on (picture mute) |
|
| ||
|
| 1st byte: Indicates fan errors, range 0 - 2. |
|
| ||||
|
| 2nd byte: Indicates lamp errors, range 0 - 2. |
|
| ||||
|
| 3rd byte: Indicates temperature errors, range 0 - 2. | ||||||
|
| 4th byte: Indicates cover open errors, range 0 - 2. |
| |||||
ERST ? | Error status query | 5th byte: Indicates filter errors, range 0 - 2. |
|
| ||||
|
| 6th byte: Indicates other errors, range 0 - 2. |
|
| ||||
|
| Definitions for each value from 0 - 2 are as follows. | ||||||
|
| 0 | = | No error known |
|
|
| |
|
| 1 | = | Warning | 2 | = | Error | |
|
| 1st digits (1 - 5 digits): | Lamp 1 cumulative operating time | |||||
LAMP ? | Lamp status query | 2nd digit: |
| 0 = Lamp 1 off, 1 = Lamp 1 on | ||||
3rd digits (1 - 5 digits): | Lamp 2 cumulative operating time | |||||||
|
| |||||||
|
| 4th digit: |
| 0 = Lamp 2 off, 1 = Lamp 2 on | ||||
|
| The following are returned as parameters. |
|
| ||||
INST ? | Input selection list query | “11 12 21 22 31” for | ||||||
|
| “11 12 21 22 31 32” for |
|
|
| |||
NAME ? | Projector name query | The name set for PROJECTOR NAME in NETWORK menu. | ||||||
INF1 ? | Manufacturer name query | “Panasonic” is returned. |
|
|
| |||
INF2 ? | Model name query | “DZ6710, DZ6700, DW6300, D6000 or D5000 is returned. | ||||||
INF0 ? | Other information query | Information such as version number is returned. |
| |||||
CLSS ? | Class information. | “1” is returned |
|
|
| |||
|
|
|
|
|
|
|
|
PJLink™ security authorization
When using PJLink™ with security authorization, either of the password set for administrator privileges and the password set for user privileges with web browser control can be used as the password for PJLink™. When using PJLink™ without security authorization, set use without the password for administrator privileges and the password for user privileges of web browser control.
PJLink™ is a pending trademark in Japan, the United States, and other countries and regions. For specifications regarding PJLink™, refer to the Japan Business Machine and Information System Industries Association website.
URL: http://pjlink.jbmia.or.jp/
Appendix
ENGLISH - 44