U S I N G T H E XCARD
The crossover functions are controlled through the use of an XCard and can be set for
|
|
|
|
|
|
|
|
➝LP |
| ➝ |
| ||||
HP |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
➝HP | LP➝ |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Full Range
FULL ↕
The crossover point can be altered by changing the resistor value. Use the following formula to select the appropriate resistor value to be placed on the XCard.
3386 | = R (in kΩ | ) for .047µ f cap | The actual formula is: | |||
fo | ||||||
|
| |||||
|
|
|
|
| ||
|
|
| R = | 1 |
| |
7234 = R (in kΩ | ) for .022µ f cap | 2π foc | ||||
|
fo
R1
Crossover Card
R2 | R1 |
High Pass |
|
Low Pass |
|
Full Range |
|
FULL
R2
Where: R = ohms
fo = desired crossover frequency c = capacitor in farads
ex: .047 x
– 13 –