ESLmanual Feb02 11/02/04 9:14 AM Page 9
ESL-988 SPECIFICATIONS
All measurements made with a 230V AC supply.
Maximum output | 2 N/m2 at 2m on axis | |
Sensitivity | 1.5m bar per volt referred to 1m. (86 dB/2.83V rms) | |
Impedance | 8 Ohms nominal | |
Maximum | Continuous input voltage (rms): 10V | |
| Programme peak for undistorted output: 40V | |
| Permitted peak input: 55V | |
Directivity Index | 125 Hz | 5.0 dB |
| 500 Hz | 6.4 dB |
| 1 kHz | 7.2 dB |
| 8 kHz | 10.6 dB |
Axis band limits | ||
(low level) | ||
AC Input | ||
(double insulated) | See rating details on base of unit | |
Power fuse | 63 mA | |
| 100 mA | |
Power consumption | 6W |
|
Dimensions | Height 94cm (including 10cm base) , width 67cm, | |
| depth 31.5cm (including terminals)approx. | |
Weight | Net 20.5 kg approx. Gross 23 kg approx. |
The right is reserved to alter performance and specification as required.
This equipment complies with the radio interference requirements as laid down in
EEC (European Economic Community) regulations.
9