BIXOLON SRP-770II user manual Gap Sensor Auto-Calibration

Page 17

SRP-770II

5-3 Gap Sensor Auto-Calibration

Gap sensor auto-calibration is used when the printer does not detect a gap on the label paper correctly.

Generally a printer is set to detect most of gap types but sometimes it fails to detect and keep feeding the paper without a stop when special paper used. In such case, use gap sensor auto-calibration function for a proper detection.

1)Make sure that paper roll has been installed properly.

2)Turn on the power while holding down FEED button with cover open. Then the Green LED blinks.

ON

3)Close the ribbon roll and paper cover.

-An information message is printed out and the red LED turns on.

4)Press the paper feed button.

Once

-The LED color changes to orange.

-The previous gap sensor correction value is erased and reset to its default value.

Twice

-The LED color changes to green.

-The gap sensor auto-calibration is performed as 2~3 pages of paper are fed continuously.

5)Gap sensor auto-calibration is complete.

Rev. 1.14

- 17 -

Image 17
Contents SRP-770II SRP-770II Table of ContentsManual Information Do not plug several products in one multi-outlet Safety PrecautionsTo Unplug Other Precautions SRP-770II Content ConfirmationProduct Part Names Auto Cutter Option Power Connection Installation & UsageUSB Interface Cable ConnectionPaper Installation LED LED DisplaySelf-Test Printer Settings with Dip switches Fine TuningPause/Restart Gap Sensor Auto-Calibration Gap Sensor Manual-Calibration Peel-Off SRP-770II Using Fan-Fold Paper ※ Caution Partial cut Auto Cutter option※ Caution Cleaning Head※ Note SpecificationsAppendix CE Mark Certification EMC & Safety StandardsWeee Waste Electrical and Electric Equipment Label Types