Nortel Networks 2750 manual Understanding the LEDs, Front panel LEDs, Front panel LED indicators

Page 40

40Chapter 2 Cabling the VPN Router and turning the power on

Understanding the LEDs

This section describes the LEDs on the front panel of the VPN Router 2750 and on the interface cards that have LEDs. You can confirm that you properly cabled the LAN and WAN interfaces by examining the LEDs.

Front panel LEDs

The front panel of the VPN Router 2750 has a lighted Nortel logo and two LEDs (Figure 8). These LEDs indicate the status of the VPN Router 2750.

Figure 8 Front panel LEDs

Alert

Boot/Ready

Power

Alert

Boot/Ready

CS160013A

Table 4 describes the LEDs on the VPN Router 2750 front panel.

Table 4 Front panel LED indicators

LED

Indicator

Description

 

 

 

Power (Nortel

On

The gateway is receiving AC power.

logo)

 

 

Off

The gateway is not receiving AC power.

 

 

 

 

Alert

Yellow

A non-fatal alarm condition exists. The yellow alert

 

 

condition is described in the health check display.

 

Red

A serious alarm condition exists that requires attention.

 

 

A red alert usually indicates a hardware error. The red

 

 

alert condition is described in the health check display.

Boot/Ready

Yellow

The gateway is booting and is in a non-ready state.

 

 

 

 

Green

The boot process is complete and the gateway is in a

 

 

state of readiness.

For complete information about the health check, event log, and system log, see

Nortel VPN Router Troubleshooting.

NN46110-318 02.01

Image 40
Contents Nortel VPN Router Installation Copyright 2007 Nortel Networks. All Rights Reserved NN46110-318Nortel VPN Router Installation VPN Router EC Declaration of ConformityCanada requirements only General NN46110-318 Contents Chapter Cabling the VPN Router and turning the power on ContentsChapter Installing option cards and DIMMs Index Figures Figures Tables Nortel VPN Router Installation VPN Router New in this release Features1000BASE-T 1000 GT Ethernet card New in this release NN46110-318 Finding the latest updates on the Nortel Web site How to get helpGetting help from the Nortel Web site Getting help over the phone from a Nortel Solutions Center How to get helpGetting help through a Nortel distributor or reseller How to get help NN46110-318 Preface Before you beginText conventions AcronymsRelated publications Printed technical manuals Description of the Nortel VPN Router Chapter Installing the Nortel VPN Router 2750 chassisTopic Preparing to install the Nortel VPN Router Installing the Nortel VPN Router 2750 chassisShipment contents Additional equipment Site requirementsInstalling the chassis Installing the chassis on a flat surfaceInstalling the chassis in an equipment rack Rack-mount recommendationsAttaching the cage nuts to the rack Mounting the chassis in the equipment rack Replacing the front bezel Installing the Nortel VPN Router 2750 chassis NN46110-318 Chapter Cabling the VPN Router and turning the power on TopicCabling the VPN Router and turning the power on Connecting communications cablesInterfaces and cables for the Nortel VPN Router Connecting the power cord Rear view of the Nortel VPN RouterPower cord requirements Power cord must meet the requirements described in TableRequirement Description Verifying a successful installation Front panel LED indicators Indicator DescriptionUnderstanding the LEDs Front panel LEDsLED indicators on the system 10/100BASE-TX Ethernet ports LEDs on the system 10/100BASE-TX Ethernet portsLED indicators on the 10/100BASE-TX Ethernet interface card 10/100BASE-TX Ethernet interface card LEDs1000BASE-T 1000 GT Ethernet interface card LEDs LED indicators on the 1000 GT Ethernet interface card1000BASE-T 1000 MT Ethernet interface card LEDs 1000BASE-SX Ethernet interface card LED LEDs on the 1000BASE-T 1000 MT Ethernet interface cardLED indicator on the 1000BASE-SX Ethernet interface card Describes the LED on the 1000BASE-SX Ethernet interface card56/64K CSU/DSU WAN interface card LEDs LED indicators on the 56/64K CSU/DSU WAN interface cardDescribes the LEDs on the 56/64K CSU/DSU WAN interface card LED indicators on the Adsl WAN interface card Adsl WAN interface card LEDsDescribes the LEDs on the Adsl WAN interface card Tx/Rx LED DescriptionT1/E1 CSU/DSU WAN interface card LEDs LED indicators on the T1/E1 CSU/DSU WAN interface cardDescribes the LEDs on the T1/E1 CSU/DSU WAN interface card LED indicators on the quad T1/E1 CSU/DSU WAN interface card Quad T1/E1 CSU/DSU WAN interface card LEDsLED indicators on the single V.35/X.21 WAN interface card Single V.35/X.21 WAN interface card LEDsLED indicators on the SSL VPN Module LEDs Indicator DescriptionSSL VPN Module 1000 LEDs Describes the LEDs on the SSL VPN ModuleCabling the VPN Router and turning the power on NN46110-318 Chapter Configuring the management IP interface Configuring the management IP interface Required informationConfiguring the management IP address Serial main menu appears Interface menu appearsOld Subnet Mask = 0.0.0.0 New Subnet Mask = Type M, and press Enter Management IP Address prompt appears Testing the configuration Troubleshooting Chapter Installing option cards and DIMMs Installing option cards and DIMMs Shutting down the system to add or replace hardwareRemoving the front bezel and top cover Installing option cards and DIMMs Removing the top cover Location of option card and Dimm slots on the system board Attaching the antistatic wrist strap Supported option cards for the Nortel VPN Router 2750 Installing and replacing option cardsMaximum Option card Number Restrictions Installing other option cards with the SSL VPN Module Installing and replacing an option cardOption card Restrictions with SSL VPN Module 1000 installed Installing option cards and DIMMs Installing and removing an option card Installing and replacing DIMMs Installing option cards and DIMMs Installing and removing a Dimm Installing option cards and DIMMs Installing option cards and DIMMs NN46110-318 Appendix a Technical specifications Chassis specificationsPhysical, electrical, and environmental specifications Specification DescriptionSystem ports 10/100BASE-TX Ethernet LAN portsAppendix a Technical specifications Serial portProvides the 10/100BASE-TX Ethernet port pinouts 10/100BASE-X Ethernet port pinoutsMultiple DB9 and DB25 connector pinouts Modem cable specificationsSerial port DB9 connector DB25 connector Nortel termination Modem termination Signal Pin # to Pin # Hardware option cardsProvides the modem cable pinouts Modem cable pinoutsVPN Router Security Accelerator Shows the VPN Router Security Accelerator cardSSL VPN Module Shows the SSL VPN Module10/100BASE-TX Ethernet interface card Shows the 10/100BASE-TX Ethernet interface card1000BASE-T 1000 GT Ethernet interface card 1000BASE-T 1000 GT Ethernet pinouts 1000BASE-T 1000 MT Ethernet interface card 1000BASE-T Ethernet port pinouts1000BASE-SX Ethernet interface card Shows the 1000BASE-SX Ethernet interface card56/64K CSU/DSU WAN interface card Shows the 56/64K CSU/DSU WAN interface cardNortel termination Remote termination Signal Pin # to Pin # 56/64K CSU/DSU cable pinouts for crossover connectionAdsl Annex a cable pinouts Adsl WAN interface cardPin Function RJ-11 termination RJ-45 termination Signal Pin # to Pin # Isdn BRI interface cardProvides the pinouts for the Adsl Annex B cable Adsl Annex B cable pinoutsProvides the Isdn BRI S/T cable pinouts Provides the Isdn BRI U cable pinoutsIsdn BRI S/T cable pinouts Isdn BRI U cable pinoutsT1/E1 CSU/DSU WAN interface card Shows the T1/E1 CSU/DSU WAN interface card half-height cardCable operates properly if you do not connect pins 3, 6, 7, T1/E1 CSU/DSU cable pinouts for crossover connectionQuad T1/E1 CSU/DSU WAN interface card T1/E1 CSU/DSU cable pinouts for straight-through connectionModem interface card 90 modem interface cardSingle V.35/X.21 WAN interface card Provides the V.90 modem port cable pinouts90 modem cable pinouts 35 cable pinoutsAppendix a Technical specifications 35 cable pinouts Signal Ground21 cable pinouts Appendix a Technical specifications 21 cable pinouts Pin Scsi male Signal nameHssi WAN interface card T3 cable pinoutsAppendix a Technical specifications T3 cable pinouts Index NumericsIndex Index Index Index WAN interface card. See single V.35/X.21 WAN interface card