Baldor NEMA 4X, IP-65 manual Fault Recovery & Resetting the Control, VII. AC Line Fusing

Page 12

TABLE 4 – FAULT RECOVERY & RESETTING THE CONTROL*

Fault

Auto Mode

Manual Mode

Auto or Manual Mode

with Start/Stop Switch Installed

with Start/Stop Switch Installed

with Start/stop Switch Removed

 

Undervoltage

Control will automatically reset.

Reset the control with the

Control will automatically reset.

Start/Stop Switch.

 

 

 

 

 

 

 

Overvoltage

Control will automatically reset.

Reset the control with the

Control will automatically reset.

Start/Stop Switch.

 

 

 

 

 

 

 

Short Circuit

Control will automatically reset.

Reset the control with the

Control will automatically reset.

Start/Stop Switch.

 

 

 

 

 

 

 

I2t

Reset the control with the

Reset the control with the

Disconnect and reconnect the AC

 

Start/Stop Switch.

Start/Stop Switch.

line.

*Fault must be cleared before the control can be reset.

WARNING! The motor will automatically start when the AC line is applied or a

!fault is cleared, if Jumper J4 is set to the “AUTO” or “MAN” position and the Start/Stop Switch is eliminated.

VII. AC LINE FUSING

This control does not contain AC line fuses. Most electrical codes require that each ungrounded conductor contain circuit protection. It is recommended to install a 20 Amp fuse (Littelfuse 326, Buss ABC or equivalent) or a circuit breaker in series with each ungrounded conductor. Check all electrical codes that apply to the application. Do not fuse motor leads.

VIII. TRIMPOT ADJUSTMENTS

The control circuit board contains trimpots, which are factory set for most applications. Figure 2, on page 3 illustrates the location of the trimpots and their approximate factory calibrated positions. Some applications may require readjustment of the trimpots in order to tailor the control for a specific requirement. Readjust trimpots as described below.

WARNING! If possible, do not adjust trimpots with ! the main power applied. If adjustments are made with the main power applied, an insulated adjustment tool must be used and safety glasses must be worn. High volt- age exists in this control. Fire and/or electrocution can result if caution is not exercised. Safety Warning, on page 1, must be read before proceeding.

A.Maximum Speed (MAX): Sets the maximum speed of the motor. The MAX trimpot is factory set for 100% of base motor speed. For a higher maximum speed setting, rotate the MAX trimpot clockwise. For a lower maximum speed setting, rotate the MAX trimpot counterclockwise. See Figure 17.

B.Minimum Speed (MIN): Sets the minimum speed of the motor. The MIN trimpot is factory set for 0% speed. For a higher minimum speed setting, rotate the MIN trimpot clock- wise. See Figure 18.

C.Acceleration (ACCEL): Sets the amount of time for the motor to accelerate from zero speed to max speed. The ACCEL trimpot is factory set for 1.5 seconds acceleration. For more rapid acceleration time, rotate the ACCEL trimpot counterclockwise. For longer acceleration time, rotate the ACCEL trimpot clockwise. See Figure 19.

Note: Rapid acceleration settings may cause the current limit circuit to activate, which will extend the acceleration time.

FIGURE 17

MAX TRIMPOT RANGE

80

75 90

100

70

110

Percent of Frequency Setting (Shown Factory Set to 100%)

FIGURE 18

MIN TRIMPOT RANGE

 

30

15

35

0

40

Percent of Frequency Setting (Shown Factory Set to 0%)

FIGURE 19

ACCEL TRIMPOT RANGE

 

5

2.5

12.5

1.5

 

0.3

20

Seconds

(Shown Factory Set to 1.5 Seconds)

D.Deceleration (DECEL): Sets the amount of time for the motor to decelerate from max speed to zero speed. The DECEL trimpot is factory set for 1.5 seconds deceleration. For

10

Image 12
Contents Series 5 Inverter Table of Contents IIISimplified Operating Instructions Standard Features IntroductionControl Layout Shown with Optional AUTO/MANUAL and FORWARD-STOP-REVERSE 208.17General Performance Specifications II. Wiring InstructionsElectrical Ratings Terminal Block Wiring Information Power ConnectionsIII. Setting Selectable Jumpers AC Line Input Voltage SelectionBoost Mode Selection IV. Mounting InstructionsMotor Frequency Multiplier Selection HI-POT Setup VI. Control OperationFault Recovery & Resetting the Control VII. AC Line FusingVIII. Trimpot Adjustments I2t Trip Time vs Motor Current Control Mode and Status LED Indication Optional Accessories XI. Limited Warranty