Galaxy 4000

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS – This manual contains important instructions for Galaxy

4000 that must be followed during operation and maintenance of the equipment.

WARNING ATTENTION WARNUNG!

WARNING ATTENTION WARNUNG!

NOTE

WARNING

ATTENTION

WARNUNG!

Opening enclosures expose hazardous voltages. Always refer service to qualified personnel only.

L'ouverture des cabinets expose des tensions dangereuses. Assurez-vous toujours que le service ne soit fait que par des personnes qualifiees.

Das öffnen der Gehäuse legen gefährliche Spannungen bloss. Service sollte immer nur von qualifizierten Personal durchgeführt werden.

As standards, specifications, and designs are subject to change, please ask for confirmation of the information given in this publication.

Comme les normes, spécifications et produits peuvent changer, veuillez demander confirmation des informations contenues dans cette publication.

Normen, Spezifizierungen und Pläne unterliegen Anderungen. Bitte verlangen Sie eine Bestätigung über alle Informationen, die in dieser Ausgabe gemacht wurden.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at user's own expense.

To reduce the risk of fire or electric shock, install in a controlled indoor environ- ment free of conductive contaminants.

This equipment is intended only for installations in a RESTRICTED ACCESS LOCATION.

Pour réduire le riske d'inccendie ou d'électrocution, installer dans une enciente intérieure contrôlée en température et humidité et sans contaminants conducteurs.

Ce matériel est destiné seulement pour des installations dans un EMPLACEMENT RESTREINT D'ACCES.

Um die Gefahr von Feuer und elektrischem Schock zu reduzieren, muss das Gerät in einem temperatur – und feuchtigkeitskontrollierten Raum, frei von leitungsfähigen Verunreinigungen, installiert werden. Dieses Gerät ist nur für die Installation an einem Ort mit qeingeschränkter Zugangserlaubnis vorgesehen.

Diese Ausrüstung ist nur für Anlagen in einem EINGESCHRäNKTEN ZUGRIFF STANDORT bestimmti.

ii

Important Safety Instructions

86-173010-00 A00

Image 4
Contents Galaxy Page Galaxy Revision HistoryImportant Safety Instructions GalaxyProduct Safety Safety of PersonsSpecial Precautions Galaxy Contents Display Panel MaintenanceOperation Warranty, Registration & Customer Support Glossary Reorder FormFigures TablesSection Descriptions ElectricalGalaxy Scope IntroductionGeneral Description Single Line Diagram Major ComponentsCabinet Placement Galaxy 4000 Standard CabinetsPreparation for Operation Heat Rejection and Air FlowHeat Rejection Data @ 208/208VAC Cabinet ClearancesConduit Plate Locations for Bottom Entry 40KVA 50KVA 65KVA 75KVAConfiguration for Bottom Entry Conduit Plate Locations for Top EntryPreparation for Storage Setup and Installation Installation StepsFinal steps by MGE Field Service Engineer Environmental and Electrical SpecificationsElectrical Connections Electrical Specifications40KVA 50KVA 65KVA Main AC Input Connections UPS ConnectionsAC Output Connections Battery Connections Remote Emergency Power Off ConnectionsInputs Relay Communication Card ContactsOutputs Relay Communication Card Connections Relay Communication Card5VDC Consumption 10 mA Cable 0.34 mm, 5 ±0.5 mmThis page left blank intentionally Operator Interface Keys and Indicators Display PanelLED Indicator Functions Green LED Orange LED Red LEDFlashing OFFDisplay Menu Structure Main Menu Screen Battery Measurements ScreenMeasurements Magnifying glass Power Measurements ScreenCurrent Measurements Screen Frequency Measurements Screen Voltage Measurements ScreenRatios Screen Mimic Diagrams Status ScreenSettings Screen Commands Screen Startup Procedure ScreenThis page left blank intentionally Display Panel Operation Pre-Startup Safety Check ListPreparing for Startup Q4S Q3BPQ5N Normal Startup Procedure Post Startup Safety Check List Shutdown ProcedureShutdown Using EPO Recovery from EPOImportant Safety Instructions for Servicing Batteries MaintenanceServicing Batteries This page left blank intentionally Applicable within the United States, Canada and Mexico Galaxy Warranty and Product Registration Warranty Extension Warranty+User Information Product InformationMGE Customer Care Center Three Phase Products Technical Support and Product ServicesScheduling Field Service Engineer Support Return Policy for Repair of Three Phase Products RGAAdditional Serial Numbers Glossary ABCIEC NEC This page left blank intentionally Reorder Form Galaxy 40 75KVAPage Page Page Page Contact MGE

40-75KVA specifications

MGE UPS Systems 40-75KVA represents a significant advancement in uninterruptible power supply technology, specifically designed to cater to the critical needs of medium to large-scale operations. These systems are integral for protecting sensitive electronic equipment and ensuring the continuity of operations during power disturbances.

One of the standout features of the MGE UPS Systems in this range is their high efficiency. With efficiency ratings often exceeding 94%, these units minimize energy loss and reduce operational costs, making them not only environmentally friendly but also financially viable. The robust design caters to a variety of applications, including data centers, telecommunications facilities, and industrial environments.

A cornerstone of the MGE UPS design is its modular architecture, allowing for scalability and flexibility. This modularity ensures that as power requirements increase or decrease, the system can be easily adjusted to meet those needs without replacing the entire unit. This adaptability is critical for businesses that experience fluctuating demand or growth.

Advanced technology is employed in the battery management system as well. MGE UPS Systems utilize intelligent battery management, which enhances battery performance and lifespan. The system continuously monitors battery health and ensures optimal charging, thus reducing the risk of failure and extending operational readiness.

The MGE UPS Systems 40-75KVA also boast user-friendly interfaces with graphical LCD displays, facilitating easy monitoring and management of the power supply status. Users can access relevant data such as load levels, battery status, and system health, simplifying troubleshooting and maintenance tasks.

Additionally, these UPS systems incorporate multiple forms of communication interfaces, including USB, RS232, and network management options, ensuring seamless integration with other system monitoring tools. This connectivity enhances operational oversight and aids in proactive management of power resources.

Furthermore, the high availability features, such as redundant components and hot-swappable modules, ensure that maintenance can be performed without interrupting operations, significantly reducing downtime.

In conclusion, MGE UPS Systems 40-75KVA encapsulate cutting-edge technology with unique features that prioritize efficiency, flexibility, and reliability. With their robust design tailored for demanding environments, they are an optimal choice for organizations seeking to safeguard their critical operations against power interruptions. The combination of advanced battery management, user-friendly interfaces, and scalable architecture makes these systems a smart investment for the future.