B&K 1794 instruction manual Unit Directly Goes to CC, Unit Directly Goes To CC

Page 25

( G ) UNIT DIRECTLY GOES TO CC.

UNIT DIRECTLY GOES

TO CC

Is Shunt Resistor open OR

Dry Soldered ?

N

Is IC LM324 OK ?

Y

Is Current select Preset

R21 Open ?

N

Is Remote Sense Terminal

Pressed ?

Y

Ensure Remote Sense Switch is Unpressed in Normal Condition.

Y

Replace Shunt Resistor

 

if necessary.

N

Replace It.

Y

Replace It.

1.Check the Shunt Resistor ( 0.025E / 25E ). It might be Open or Dry Soldered.

2.Check IC LM 324. It might be Damaged.

3.Current select Preset R21 might be Open.

6.Remote Sense Terminal might be Pressed on No Load.

22

Image 25
Contents BK Precision Limited Two Year Warranty Table of Contents Limit Setting Output ON/OFF SwitchSection General Information Description Remote Programming With External 5K PotSection Specifications Section Installation Repackaging for Shipment Input TAP Selection for 230V OperationSection Operating Instructions Readjust the current limit in the remote sensing mode Reverse Voltage Loading Output CapacitanceReverse Current Loading USE the Proper Power Cord Operators Safety SummaryTerms in this Manual Terms AS Marked on Equipment For Qualified Service Personnel only Servicing Safety SummaryDo not Service Alone USE Care When Servicing with Power onTrouble Shooting Techniques Section Service Instruction GeneralServicing shall be done only by Qualified personnel Repairs & Maintenance Page Parts Ordering & Replacing REF. PCB no PIN noPage Page Fuse Blows Fault Finding ProcedureFuse Blows Unregulated O/P Voltage Unregulated O/P VoltageNo O/P Voltage No Output VoltageNo DPM Indication No DPM IndicationDPM not Read Unit not Take Current Unit not Take CurrentUnit Directly Goes To CC Unit Directly Goes to CCPoor Line Regulation No Current ControlNo Current Control Poor Line RegulationCV, CC, LED not Glow Poor Load RegulationPoor Load Regulation Remote Sense not OK External Programming not OKExternal Programming Not OK L1791-FP-CNT-0603 PCB Assy Section Part List & Schematics1KPF/100V, Disc 2P2W SW Push ButtonPS-PREG-1791-0503 PCB Assly SW1 Grey Colour CAP for Push Switch SW2 SW3DPM/01 REV 01 X PS-PWR-L1791-0703A PCB Assly PS-AUX-DC-L1791-0503 PCB AsslyMain Chassis Assly Front Panel AsslyBack Trough Assly Front Panel Layout Back Panel Layout TOP View Bottom View of Model 1790 Front Panel Control PCB of 1790 Power Module PCB of 1790 PRE Regulator / AUX. P/S PCBs 1790 Precision Corp Service InformationPrecision Corp