GENERAL INFORMATION

1.1DESCRIPTION :

The 1794 High Current Regulated D.C. Power Supply is completely solid and suitable for bench operation or standard 19" rack operation. It is a well regulated constant voltage / constant current supply which delivers 0-32V at 0-20Amps and can be adjusted continuously throughout the output range. When the supply is used as a constant voltage source the front panel VOLTAGE controls can be used to limit the output voltage. When the unit is used as a constant current source, the front panel CURRENT controls can be used to limit the output current. The unit will automatically cross over from constant voltage to current mode and vice-versa if the output current or voltage exceeds these limits.

Output voltage and current are continuously monitored on two front panel meters. The load terminals and remote sense terminals are provided on the front panel. Either the positive or negative output terminal may be grounded or the power supply can be operated floating at upto a maximum of ±300VDC above ground.

1.2OUTPUT ON/OFF SWITCH :

The output voltage and Current can be preset without connecting the power supply to the load. With the OUTPUT ON/OFF switch in the OFF position, the maximum voltage and current limits can be set. Pressing the OUTPUT ON switch connects the output of the power supply to the load.

1.3LIMIT SETTING :

The voltage and current limits can be set when the output is not connected to the load. With the OUTPUT ON/OFF switch in the OFF position and the LIMIT switch pressed, the voltage and current limits can be set with the front panel VOLTAGE and CURRENT potentiometers.

1.4REMOTE PROGRAMMING ( With External 5K Pot ) :

The output voltage of the unit can be programmed between 0 to 32V by means of an external remote programming voltage resistor. An external resistance programming selector link is provided on the rear panel for this purpose.

1.5REMOTE SENSING :

The degradation in regulation which occurs at the load due to voltage drop in the load leads can be eliminated by using the power supply in the remote sensing mode operation. The remote sensing mode is selected by a push switch on the front panel.

1

Image 4
Contents BK Precision Limited Two Year Warranty Table of Contents Output ON/OFF Switch Limit SettingSection General Information Description Remote Programming With External 5K PotSection Specifications Section Installation Input TAP Selection for 230V Operation Repackaging for ShipmentSection Operating Instructions Readjust the current limit in the remote sensing mode Reverse Voltage Loading Output CapacitanceReverse Current Loading USE the Proper Power Cord Operators Safety SummaryTerms in this Manual Terms AS Marked on Equipment Servicing Safety Summary For Qualified Service Personnel onlyDo not Service Alone USE Care When Servicing with Power onTrouble Shooting Techniques Section Service Instruction GeneralServicing shall be done only by Qualified personnel Repairs & Maintenance Page REF. PCB no PIN no Parts Ordering & ReplacingPage Page Fuse Blows Fault Finding ProcedureFuse Blows Unregulated O/P Voltage Unregulated O/P VoltageNo Output Voltage No O/P VoltageNo DPM Indication No DPM IndicationDPM not Read Unit not Take Current Unit not Take CurrentUnit Directly Goes to CC Unit Directly Goes To CCNo Current Control Poor Line RegulationNo Current Control Poor Line RegulationCV, CC, LED not Glow Poor Load RegulationPoor Load Regulation Remote Sense not OK External Programming not OKExternal Programming Not OK Section Part List & Schematics L1791-FP-CNT-0603 PCB Assy1KPF/100V, Disc 2P2W SW Push ButtonSW1 Grey Colour CAP for Push Switch SW2 SW3 PS-PREG-1791-0503 PCB AsslyDPM/01 REV 01 X PS-AUX-DC-L1791-0503 PCB Assly PS-PWR-L1791-0703A PCB AsslyMain Chassis Assly Front Panel AsslyBack Trough Assly Front Panel Layout Back Panel Layout TOP View Bottom View of Model 1790 Front Panel Control PCB of 1790 Power Module PCB of 1790 PRE Regulator / AUX. P/S PCBs 1790 Service Information Precision CorpPrecision Corp