American Power Conversion HI600SQ user manual Controls and Indicators, Home UPS Connections

Page 5

12V Battery

 

 

 

 

+Ve

 

INPUT

 

OUTPUT

N

L

L

N

-Ve

Push to Reset

 

 

 

 

 

 

 

 

 

 

Input

: 230V, 5A, 50Hz

 

 

 

Output : 230V, 5A, 50HZ

 

These connectors are provided

 

 

 

 

with the Home UPS Assembly

 

 

 

Battery Wiring Output Harness

and must be installed

 

 

 

(Red and Black Wires)

on to the wiring.

 

 

 

 

From Electricity Board Meter

 

 

 

 

(through Double-Pole

 

 

 

 

Switch Lighting Circuit)

 

 

 

 

To Load

 

 

 

Figure 3. Home UPS Connections

Section 4. Controls and Indicators

Please review this section thoroughly before applying power to the Home UPS.

Home UPS Controls - Controls provided on the Home UPS consist of the holiday mode switch marked AWAY/HOME, and the Test/Mute switch, as well as a rear panel Push to Reset circuit breaker, and are defined in the following:

AWAY/HOME - (also known as the holiday mode switch) - In the HOME position, this two-position rocker switch (Figure 4) sets the Home UPS so that it will switch to battery output when there is a utility power outage.

In the AWAY position, the Home UPS goes into standby mode and will not switch to battery power in the event of a power outage. This is to conserve the batteries. However, in this position, the Home UPS will charge the batteries until a utility power failure occurs.

TEST/MUTE - In TEST mode, when ON MAINS LED is lit, on pressing this push button, the unit will do self test to determine the state of the system. During On Battery self test it will also show the load status which can be used to find out the load capacity. In the MUTE position (push in for 5 seconds), this push button switch silences the low battery buzzer.

Circuit Breaker Switch (Rear Panel) - When in ON MAINS mode, if the system draws more than 10A, circuit breaker will trip. To reset the circuit breaker switch, push the switch fully inward.

Home UPS Indicators - The Home UPS provides light emitting diode (LED) indicators (Figure 4) to show the operational condition of the Home UPS and batteries. Indicators consist of Inverter Load Status (25%, 50%, 75%, 100%, and OVER LOAD). Other indicators consist of: INVERTER DISABLE, ON MAINS, ON BATTERY, and FAULT). Using Table 1, determine the condition of the Home UPS and battery.

Cold Boot - To turn on the Home UPS on Battery Mode, press the Test-Mutebutton and hold it for 2-3 seconds.

Page 3

Image 5
Contents HI600SQ Contents Unpacking/Inspection of Home UPS at customer location Unpacking/Inspection of Home UPS at reseller locationHome UPS Placement InstallationControls and Indicators Away Test Mute Home Home UPS faults TroubleshootingPush to Reset Input 5A, 50Hz Output 5A, 50HZ Contact Information SpecificationsWarranty