Agilent Technologies 665xA, 664xA, 667xA, 669xA manual Outprel 1 Outprel OFF, Outprelpol Norm

Page 40

OUTP:REL

Do not install or program the Agilent Relay Accessories if the power supply maximum output current rating (see Table 3-1) exceeds the contact ratings of the relay.

This command is valid only if the power supply is configured for the optional relay connector. Programming ON closes the relay contacts; programming OFF opens them. The relay is controlled independently of the output state. If the power supply is supplying power to a load, that power will appear at the relay contacts during switching. If the power supply is not configured for the relay option, sending either relay command generates an error.

Command Syntax

OUTPut:RELay[:STATe] <bool>

Parameters

0

1 OFF ON

*RST Value

0

 

Examples

OUTP:REL 1 OUTP:REL OFF

Query Syntax

OUTPput:RELay?

Returned Parameters

0

1

Related Commands

OUTP[:STAT] *RCL *SAV

OUTP:REL:POL

Do not install or program the Agilent Relay Accessories if the power supply maximum output current rating (see Table 3-1) exceeds the contact ratings of the relay.

This command is valid only if the power supply is configured for the optional relay connector. Programming NORMal causes the relay output polarity to be the same as the power supply output. Programming REVerse causes the relay output polarity to be opposite to that of the power supply output. If OUTP[:STAT] = ON when either relay command is sent, the power supply output voltage is set to 0 during the time that the relays are changing polarity.

If the power supply is not configured for the relay option, sending either relay command generates an error.

Command Syntax

OUTPut:RELay:POLarity <CRD>

Parameters

NORMal REVerse

*RST Value

NORM

Examples

OUTP:REL:POL NORM

Query Syntax

OUTPput:RELay:POLarity?

Returned Parameters

NORM REV

Related Commands

OUTP[:STAT] *RCL *SAV

40 Language Dictionary

Image 40
Contents Programming Guide Gpib DC Power Supplies Agilent Part No Microfiche Part No JulySafety Guidelines Printing HistoryContents Description of Subsystem Commands System CommandsCurrent Subsystem Display SubsystemCommand Summary Programming Parameters Power Supply Status Structure Operation Status GroupVoltage Subsystem Questionable Status GroupPage General Information About this GuideDocumentation Summary User’s GuidePrerequisites for Using this Guide VXIplug&play Power Product Instrument DriversDownloading and Installing the Driver Accessing Online HelpGpib Capabilities Of The Power Supply Remote ProgrammingIntroduction To Scpi ConventionsTypes of Scpi Commands Scpi MessagesStructure of a Scpi Message Voltlev 4.5PROT 4.8CURR?NLVolt LEV Prot Curr Parts of a Scpi MessageVoltlev 4.5 Prot 4.8 CURR? Traversing the Command Tree Query IndicatorMessage Unit Separator Root SpecifierEffect of Optional Headers Moving Among SubsystemsOutputprotectionclear STATUSOPERATIONCONDITION? OUTPUTPROTECTIONCLEARSTATUSOPERATIONCONDITION?Including Common Commands Scpi QueriesValue Coupling Scpi Data FormatsExamples Controlling the Output Writing to the Display Saving and Recalling StatesProgramming Status System Considerations Programming the Digital I/O PortGpib Address DigdataAction Display Shows Assigning the Gpib Address In ProgramsError Handling DOS DriversAgilent Basic Controllers Sample Program CodeProgramming Some Power Supply Functions Iout = OUTPUTS2Call Ioenter PS,OEVENT SPOL%=O While C O Language Dictionary IntroductionDescription Of Common Commands Common Commands Syntax DiagramCLS ESEIDN? ESR?OPC OPC? OPT?PSC PSC 0 *PSCCommand Syntax RCL NRf Parameters Example Query Syntax None Related CommandsRCL PSC *RST *SAVSAV RSTSAV Bit Configuration of Status Byte Register SRESTB? SRETST? TRGWAI Description of Subsystem Commands Calibration CommandsAbor AborCurr Currtrig Current SubsystemCurrprotstat Display Subsystem DigdataDisp Digdata 7 DigitaldatavalueDisptext Defaultmode DispmodeDisptext Dispmode Norm Displaymode Normal Displaywindowmode TextInitiate Subsystem Measure SubsystemInit Initcont MEASCURR? MEASVOLT?Outp Output SubsystemOutpprotcle Outpprotdel Outprel OutprelpolOutprel 1 Outprel OFF Outprelpol NormStatus Subsystem StatpresStatus Operation Registers STATOPER?STATUSOPERATIONENABLE? StatoperenabStatoper NTR Statoper PTR Statoperenab 1312 StatoperenabStatus Questionable Registers STATQUES?STATQUESCOND? StatquesenabSystem Commands SYSTERR? SYSTEMERROR?Statques NTR Statques PTR SYSTERR?Trigger Subsystem SystlangSYSTVERS? TrigVoltage Subsystem TrigsourVolt Volttrig Trigsour BUS Triggersource BUSCommand Summary Command SummaryCommand Parameters Subsystem Commands VoltprotCommand Parameters Common Commands ParametersProgramming Parameters Currlevtrig MAXVoltlevtrig MAX Voltprot MAXPage Power Supply Status Structure Register CommandsStatus Reporting Operation Status GroupCAL WTGUNR OPCStatus Questionable Commands Register Query Cleared By Questionable Status GroupStandard Event Status Group STATQUESNTR?Service Request Enable Register Initial Conditions At Power OnStatus Byte Register Output QueuePON Power-On Bit Servicing an Operation Status Mode EventDefault Power On Register States Condition Caused By StatpreAdding More Operation Events Monitoring Both Phases of a Status TransitionServicing Questionable Status Events Scpi Command Completion DFI Discrete Fault IndicatorRI Remote Inhibit WAIPage Error Messages Power Supply Hardware Error MessagesCalibration Error Messages System Error MessagesSummary of System Error Messages Error Error String Description/Explanation/Examples NumberScpi Confirmed Commands1 Scpi Approved CommandsScpi Conformance Information Scpi VersionNON-SCPI Commands1 Parallel Polling Compatibility LanguageCompatibility Language Volt CurrVSET? ISET? CURR? VOUT?Hold OFF VolttrigHold CurrtrigFAULT? UNMASK?SRQ OFF SRQIndex IndexOperation status group, 51 optional header Trig SOUR, 46 VOLT, 46 Volt PROT, 47 Volt Trig United States Latin America Canada Australia/New ZealandEurope Asia Pacific Japan
Related manuals
Manual 142 pages 24.05 Kb Manual 67 pages 46.05 Kb

668xA, 669xA, 667xA, 664xA, 665xA specifications

Agilent Technologies has long been a pioneer in the production of high-performance electronic test and measurement instruments, particularly in the field of power sources. Among its notable offerings are the Agilent 667xA, 669xA, 665xA, 664xA, and 668xA series of power supplies. These instruments are designed to provide stable, reliable power for a variety of applications, including electronic testing, industrial processes, and research laboratories.

The Agilent 667xA series is characterized by its programmability and advanced measurement functions. These power supplies support a wide range of output voltages and currents, allowing for flexible configurations that cater to different testing needs. The built-in measurement capabilities enable users to monitor the voltage, current, and power with high precision, which is essential for ensuring optimal performance in electronic applications.

The Agilent 669xA series stands out with its high-power outputs, making it suitable for demanding applications. These power supplies deliver high voltage and current levels, making them ideal for testing high-performance devices, such as power amplifiers and motor drives. Additionally, the 669xA series includes features such as overvoltage protection and complex output sequencing to enhance the safety and reliability of the testing process.

The Agilent 665xA and 664xA series focus on delivering high accuracy and excellent regulation. These models are particularly known for their low noise operation, which is critical for sensitive applications where precision is paramount. The integrated programming capabilities allow users to automate testing sequences, thus improving efficiency in research and development settings.

The 668xA series features advanced digital signal processing that enhances the precision and stability of the output. Users benefit from features like remote sensing and monitoring, allowing feedback adjustments that maintain output accuracy despite cable losses. Furthermore, the 668xA models can integrate seamlessly with various test environments thanks to their LAN, GPIB, and USB connectivity options.

Overall, the Agilent 667xA, 669xA, 665xA, 664xA, and 668xA power supplies provide a comprehensive range of solutions for diverse electronic testing needs. With their advanced features, superb measurement capabilities, and robust performance, these instruments empower engineers and researchers to conduct their work with confidence, precision, and efficiency.