Agilent Technologies Comprehensive Manual for Agilent E3610A Series DC Power Supplies

Page 1

￿￿

Agilent E361xA 60W BENCH SERIES DC POWER SUPPLIES

OPERATING AND SERVICE MANUAL FOR MODELS:

Agilent E3614A

Agilent E3615A

Agilent E3616A

Agilent E3617A

Manual Part No. 5959-5310

April 2000

 

Edition 8

1-1

Image 1
Contents April Agilent E361xA 60W Bench Series DC Power SuppliesSafety Summary Operating Instructions General Information Meter Programming Resolution Operating Temperature RangeTemperature Coefficient Line FuseInstallation Data InstallationInput Power Requirements Initial InspectionPower Cord TURN-ON Checkout ProcedureOperating Instructions Connecting Loads Local Operating ModeOperating Modes Operation Beyond Rated OutputRemote Voltage Sensing Remote Operating ModesRemote Analog Voltage Programming Normal Parallel Operation MULTIPLE-SUPPLY OperationAUTO-PARALLEL Operation Gramming according to the remote-programming instructions Normal Series OperationTotal output voltage to ground must not exceed 240 Vdc AUTO-SERIES Operation= slave output voltage AUTO-TRACKING OperatonLoad Considerations Service Information Test Equipment Required MaintenanceOperation Verification Tests Performance Tests Type Required Characteristics USE Recommended ModelMeasurement Techniques Load Regulation Load Effect Constant Voltage CV TestsLine Regulation Source Effect Load Transient Response TimePardrms Measurement PARDRipple and NoisePARDPeak-to-Peak Measurement CV Drift Stability Constant Current CC TestsCC Drift Stability Adjustment and Calibration ProcedureOverall Troubleshooting Procedure TroubleshootingReference and Bias Circuit Regulating Loop TroublesOvervoltage Protection Circuit Troubles Symptom Checks and Probable CausesStep Action Response Probable Cause Step Measure Response Probable Cause Replaceable Parts Table A-10. Replaceable Parts List Table A-10. Replaceable Parts List Contd R28,111 0698-3228 Resistor 49.9K +-1% .125W TF TC=0+-100 RESISTOR-VAR 10K +-10% ALL IC V RGLTR-FXD-POS 4.8/5.2V TO-220 PKG ALL DIODE-GEN PRP 180V 200MA DO-35 ALL Table A-11. Component Value Model Page Page Page Page Manual Supplement T E Constant Voltage ModeProgramming Voltage Common to the Minus Output Alternative Voltage Programming Using ResistorsProgramming Voltage Common to the Minus Output Constant Current with Voltage Programming Constant Current ModeCurrent Monitoring Remote Resistor Programming, Constant Voltage Remote Resistor Programming ConnectionsRemote Resistor Programming, Constant Current Certification Declaration of Conformity