PREPARING A LOCATION FOR THE PRINTER
Place the machine on a level and sturdy surface that can withstand the machine weight – 20.4 kg (45lb) (B6200) or 22.6 kg (50lb) (B6300). If tilted, the machine may fall over and cause injuries.
SPACE REQUIREMENTS
The printer has ventilation holes on the side and rear panels. Ensure that the printer is installed with a minimum clearance of 255mm (10in) from the rear vent to any wall, 200mm (8in) from the left vent to any wall, and 300mm (12in) from the right vent to any wall. A poorly ventilated machine can cause excessive internal heat and fire. The following diagram shows the minimum clearances required for normal operation, consumables replacement, and maintenance to ensure your machine operates at peak performance.
200 mm | 255 mm | |
8’’ | ||
10” | ||
| ||
402 mm |
| |
16” | 300 mm | |
| ||
| 12” |
* B6200
ENVIRONMENT
Ensure that the installation location meets the following conditions:
•Do not place the printer in a hot, humid, dusty or poorly ventilated environment. Prolonged exposure to such adverse conditions can result in fire or electric shock.
12 > INSTALLATION AND RELOCATION PROCEDURE