360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com
4 CONDUCTED EMISSIONS
4.1SITE AND TEST DESCRIPTION
The power line conducted emission measurements were performed in a Series 81 type shielded enclosure manufactured by Rayproof. The EUT was assembled on a wooden table 80 centimeters high. Power was fed to the EUT through a 50 ohm /50 microhenry Line Impedance Stabilization Network (EUT LISN). The EUT LISN was fed power through an A.C. filter box on the outside of the shielded enclosure. The filter box and EUT LISN housing are bonded to the ground plane of the shielded enclosure. A second LISN, the peripheral LISN, provides isolation for the EUT test peripherals. This peripheral LISN was also fed A.C. power. A metal power outlet box, which is bonded to the ground plane and electrically connected to the peripheral LISN, powers the EUT host peripherals.
The spectrum analyzer was connected to the A.C. line through an isolation transformer. The
SanDisk Corporation | Page 9 of 17 |
DoC Report |
|
2006137 |
|
04/27/07 |
|