Siemens manual Installation Procedure, Installing the PSFR-CP41

Page 16

Installing the PSFR-CP41

Mounting the PSFR-CP41 in a Rack

Installation Procedure

i

Place the PSFR-CP41 so the rear fan vent and the front intake vents remain clear of obstructions to ensure proper airflow.

1.Remove the router from the protective bag.

2.Determine where the PSFR-CP41 will be mounted.

3.Remove any blanking panels and other equipment from the chosen rack location.

4.Install the cage nuts on the vertical mounting rails in the rear of the rack cabinet.

U42093-J-Z716-1-74

Operating Manual

Image 16
Contents Fibre Channel to Scsi Router PSFR-CP41 Comments… Suggestions… Corrections… Copyright and TrademarksIntroducing the PSFR-CP41 Features FeaturesFibre Channel Features Configuration Features Scsi Bus FeaturesManagement Features Specifications Point-to-Point PSFR-CP41 BenefitsIntroducing the PSFR-CP41 Multi-Initiator Single InitiatorPSFR-CP41 Benefits Availability ConnectivityDistance PerformanceHow the PSFR-CP41 Works How the PSFR-CP41 WorksOperating as Both a Scsi and Fibre Channel Device Scsi SideFibre Channel Side Mapping DevicesProcessing Scsi Information Processing Scsi InformationProcessing Fibre Channel Information Location Installing the PSFR-CP41Unpacking the Box Mounting the PSFR-CP41 in a Rack Materials neededRequired tools Mounting the PSFR-CP41 in a RackInstallation Procedure Installing the PSFR-CP41Mounting the PSFR-CP41 in a Rack Mounting at front of rack Mounting the PSFR-CP41 in a Rack Installing the PSFR-CP41 Interfaces and Connections ScsiFibre Channel Connection Scsi Connection PSFR-CP41 Scsi connection Ethernet Connection Serial Port Connection Autobaud Feature Connecting the Power Cord MIB Fibre Channel Interface Information Management Information Base MIBManagement Information Base MIB MIB Scsi Interface Information MIB Ethernet and Serial Interfaces InformationUnderstanding the PSFR-CP41 Configuration Understanding the PSFR-CP41 Configuration Soft Addressing General Fibre Channel ConfigurationHard Addressing General Scsi Configuration Fibre Channel Host to Scsi Target ConfigurationAddress Mapping Indexed AddressingIndexed Addressing Scsi BustargetlunAuto Addressing SCC AddressingConfiguring the PSFR-CP41 Operation Indicators Operation IndicatorsFault EthernetHost Device Configuration Device Management SerialEthernet/Web-Browser Device ManagementType Setting Configuring the PSFR-CP41Communicating with the PSFR-CP41 Setting Up Serial Port Communications Setting Up Serial Port CommunicationsPower Up Menu Baud Rate Configuration Perform ConfigurationPerform Configuration Fibre Channel Configuration Scsi ConfigurationEthernet Configuration Fibre Channel-to-SCSI Mapping ConfigurationSCSI-to-Fibre Channel Mapping Configuration This is not used in Siemens ConfigurationsRestore Last Saved Configuration Save ConfigurationReset Configuration to Factory Defaults Display Post Status Display Trace and Assertion HistoryReboot RebootDownload Firmware To download firmwareDowloading a new revision of the firmware Configuring the PSFR-CP41’s Ethernet Port Snmp Configuration Toggle TrapSnmp Configuration with Traps Enabled Snmp Configuration with Traps EnabledGET and SET Community Names IP Address for TrapsTroubleshooting IndicatorsBasic Verification Troubleshooting Verify Scsi Bus ConfigurationBasic Verification Verify Fibre Channel Connection Verify ConfigurationVerify Scsi Devices in NT Verify Host Configuration RS-232 Port ProblemsVerify Addressing Verify DevicesRunning Diagnostics Contact Siemens supportRJ-11 Serial and RJ-45 Ethernet Pin Assignments Appendix aPin No Function Appendix B Addressing, Structures and OperationAddressing, Structures and Operation Codes DescriptionAddressing, Structures and Operation SCC Addressing Option SCC Addressing OptionIndexed Addressing Option Appendix BAuto Assigned Addressing Option Auto Assigned Addressing OptionAppendix C Reference StandardsGlossary Fault LED ClustersDevice DifferentialFC Adapter FC DeviceFC Port FC-SCSI Hardware Path IDFibre Channel FC Fibre Channel Arbitrated Loop FC-ALFibre Channel Protocol for Scsi FCP FrameInitiator LinkLongwave Loop AddressMapping Table MultiplexerMotherboard NPortPower On Self Test Post Reset ScsiOnline OriginatorSCC Addressing Scsi AdapterScsi Addressing Scsi BusScsi Status ShortwaveSpeed TargetTopology TrapView Node Name View Port NameEnvironmental protection Environmentally friendly product design and developmentTake-back, recycling and disposal Tel. +49 5251 Fax. +49 5251Further information on environmental protection Augsburg Tel. +49 821 Fax. +49 821Comments Suggestions Corrections

PSFR-CP41 specifications

The Siemens PSFR-CP41 is a sophisticated device designed for applications in industrial automation and control systems. It serves as an essential component for monitoring and managing the functionalities of programmable logic controllers (PLCs) and other automation devices. The PSFR-CP41's main features include its robust construction, versatility, and advanced communication capabilities, making it a favored choice for engineers and system integrators worldwide.

One of the standout characteristics of the PSFR-CP41 is its compatibility with various Siemens automation systems, enhancing its flexibility in diverse applications. It supports multiple communication protocols, allowing seamless integration into existing infrastructure. This compatibility ensures that users can upgrade their facilities without extensive modifications, providing a cost-effective solution for companies looking to modernize their systems.

The PSFR-CP41 also boasts advanced processing power, enabling it to handle complex tasks efficiently. Its real-time data processing capability ensures that critical information is delivered promptly, facilitating quick decision-making processes in dynamic environments. Furthermore, its high level of reliability is crucial for industrial applications where downtime can lead to significant losses.

In terms of connectivity, the PSFR-CP41 is equipped with multiple input/output (I/O) ports, which facilitates interaction with a wide range of sensors and actuators. This feature allows the device to be deployed in various scenarios, from simple monitoring tasks to intricate control mechanisms in manufacturing plants.

Another notable technology integrated into the PSFR-CP41 is its ability to perform diagnostics and troubleshooting. The device can identify faults and provide detailed reports, enabling maintenance teams to address issues proactively. This diagnostic capability minimizes downtime and enhances operational efficiency.

The user interface of the PSFR-CP41 is designed for ease of use, featuring intuitive controls and clearly defined indicators. This design consideration fosters a positive user experience, making it accessible even for those with limited technical expertise.

In summary, the Siemens PSFR-CP41 is an advanced industrial automation component characterized by its exceptional compatibility, robust processing capabilities, and comprehensive diagnostic features. Its ability to facilitate seamless communication between various devices and systems positions it as a crucial resource for enhancing operational efficiency and productivity in various industrial settings. With a focus on reliability and user-friendliness, the PSFR-CP41 marks a significant advancement in the field of automation technology.