Siemens PSFR-CP41 manual Indexed Addressing Option, Appendix B

Page 66

Appendix B

Indexed Addressing Option

Indexed Addressing Option

Indexed Addressing allows for host bus adapter drivers that only use Peripheral Device addressing to access SCSI devices attached to the PSFR-CP41 unit. This is done by use of a table which is indexed by sequential LUN values, indicating selected BUS:TARGET:LUN devices. It is not possible in this mode to address the PSFR-CP41 unit as a controller unit directly when using the Indexed Addressing option. The size of the table is equal to the number of busses times the number of targets per bus, less one initiator ID per bus, times the number of LUNs per target. The index table can be manually edited. Config- uration tools allow for the table to be filled in order of increasing bus, target, or LUN, as may be desired for the specific requirements needed. A method is also provided to perform device discovery, and fill the table in the order that devices are discovered on the SCSI busses. As an example, if there are three devices connected to the SCSI bus at BUS:TARGET:LUN 0:0:0, 0:1:0 and 0:2:0, The Indexed table will look like Table “Example of Fibre Channel-to-SCSI mapping table”.

i

The - indicates a null entry.

FC_LUN

 

BUS

TGT

LUN

 

 

 

 

 

0x00

 

0

0

0

 

 

 

 

 

0x01

 

0

1

0

 

 

 

 

 

0x02

 

0

2

0

 

 

 

 

 

0x03

 

-

-

-

 

 

 

 

 

:

:

:

:

:

 

 

 

 

 

:

:

:

:

:

 

 

 

 

 

0x0B

 

-

-

-

 

 

 

 

 

0x0C

 

-

-

-

 

 

 

 

 

0x0D

 

-

-

-

 

 

 

 

 

0x0F

 

-

-

-

 

 

 

 

 

Example of Fibre Channel-to-SCSI mapping table

U42093-J-Z716-1-74

Operating Manual

Image 66
Contents Fibre Channel to Scsi Router PSFR-CP41 Comments… Suggestions… Corrections… Copyright and TrademarksIntroducing the PSFR-CP41 Features FeaturesFibre Channel Features Scsi Bus Features Configuration FeaturesManagement Features Specifications PSFR-CP41 Benefits Point-to-PointIntroducing the PSFR-CP41 Single Initiator Multi-InitiatorPSFR-CP41 Benefits Distance AvailabilityConnectivity PerformanceHow the PSFR-CP41 Works How the PSFR-CP41 WorksFibre Channel Side Operating as Both a Scsi and Fibre Channel DeviceScsi Side Mapping DevicesProcessing Scsi Information Processing Scsi InformationProcessing Fibre Channel Information Installing the PSFR-CP41 LocationUnpacking the Box Required tools Mounting the PSFR-CP41 in a RackMaterials needed Mounting the PSFR-CP41 in a RackInstallation Procedure Installing the PSFR-CP41Mounting the PSFR-CP41 in a Rack Mounting at front of rack Mounting the PSFR-CP41 in a Rack Installing the PSFR-CP41 Interfaces and Connections ScsiFibre Channel Connection Scsi Connection PSFR-CP41 Scsi connection Ethernet Connection Serial Port Connection Autobaud Feature Connecting the Power Cord Management Information Base MIB MIB Fibre Channel Interface InformationManagement Information Base MIB MIB Scsi Interface Information MIB Ethernet and Serial Interfaces InformationUnderstanding the PSFR-CP41 Configuration Understanding the PSFR-CP41 Configuration General Fibre Channel Configuration Soft AddressingHard Addressing General Scsi Configuration Fibre Channel Host to Scsi Target ConfigurationAddress Mapping Indexed AddressingIndexed Addressing Scsi BustargetlunAuto Addressing SCC AddressingConfiguring the PSFR-CP41 Fault Operation IndicatorsOperation Indicators EthernetHost Device Configuration Ethernet/Web-Browser Device ManagementSerial Device ManagementConfiguring the PSFR-CP41 Type SettingCommunicating with the PSFR-CP41 Setting Up Serial Port Communications Setting Up Serial Port CommunicationsPower Up Menu Perform Configuration Baud Rate ConfigurationPerform Configuration Fibre Channel Configuration Scsi ConfigurationEthernet Configuration Fibre Channel-to-SCSI Mapping ConfigurationSCSI-to-Fibre Channel Mapping Configuration This is not used in Siemens ConfigurationsSave Configuration Restore Last Saved ConfigurationReset Configuration to Factory Defaults Display Post Status Display Trace and Assertion HistoryDownload Firmware RebootReboot To download firmwareDowloading a new revision of the firmware Configuring the PSFR-CP41’s Ethernet Port Snmp Configuration Toggle TrapGET and SET Community Names Snmp Configuration with Traps EnabledSnmp Configuration with Traps Enabled IP Address for TrapsTroubleshooting IndicatorsVerify Scsi Bus Configuration Basic Verification TroubleshootingBasic Verification Verify Configuration Verify Fibre Channel ConnectionVerify Scsi Devices in NT Verify Addressing Verify Host ConfigurationRS-232 Port Problems Verify DevicesRunning Diagnostics Contact Siemens supportAppendix a RJ-11 Serial and RJ-45 Ethernet Pin AssignmentsPin No Function Appendix B Addressing, Structures and OperationAddressing, Structures and Operation Codes DescriptionAddressing, Structures and Operation SCC Addressing Option SCC Addressing OptionIndexed Addressing Option Appendix BAuto Assigned Addressing Option Auto Assigned Addressing OptionAppendix C Reference StandardsGlossary Device Fault LEDClusters DifferentialFC Port FC AdapterFC Device FC-SCSI Hardware Path IDFibre Channel Protocol for Scsi FCP Fibre Channel FCFibre Channel Arbitrated Loop FC-AL FrameLongwave InitiatorLink Loop AddressMotherboard Mapping TableMultiplexer NPortOnline Power On Self Test PostReset Scsi OriginatorScsi Addressing SCC AddressingScsi Adapter Scsi BusSpeed Scsi StatusShortwave TargetView Node Name TopologyTrap View Port NameTake-back, recycling and disposal Environmental protectionEnvironmentally friendly product design and development Tel. +49 5251 Fax. +49 5251Further information on environmental protection Augsburg Tel. +49 821 Fax. +49 821Comments Suggestions Corrections

PSFR-CP41 specifications

The Siemens PSFR-CP41 is a sophisticated device designed for applications in industrial automation and control systems. It serves as an essential component for monitoring and managing the functionalities of programmable logic controllers (PLCs) and other automation devices. The PSFR-CP41's main features include its robust construction, versatility, and advanced communication capabilities, making it a favored choice for engineers and system integrators worldwide.

One of the standout characteristics of the PSFR-CP41 is its compatibility with various Siemens automation systems, enhancing its flexibility in diverse applications. It supports multiple communication protocols, allowing seamless integration into existing infrastructure. This compatibility ensures that users can upgrade their facilities without extensive modifications, providing a cost-effective solution for companies looking to modernize their systems.

The PSFR-CP41 also boasts advanced processing power, enabling it to handle complex tasks efficiently. Its real-time data processing capability ensures that critical information is delivered promptly, facilitating quick decision-making processes in dynamic environments. Furthermore, its high level of reliability is crucial for industrial applications where downtime can lead to significant losses.

In terms of connectivity, the PSFR-CP41 is equipped with multiple input/output (I/O) ports, which facilitates interaction with a wide range of sensors and actuators. This feature allows the device to be deployed in various scenarios, from simple monitoring tasks to intricate control mechanisms in manufacturing plants.

Another notable technology integrated into the PSFR-CP41 is its ability to perform diagnostics and troubleshooting. The device can identify faults and provide detailed reports, enabling maintenance teams to address issues proactively. This diagnostic capability minimizes downtime and enhances operational efficiency.

The user interface of the PSFR-CP41 is designed for ease of use, featuring intuitive controls and clearly defined indicators. This design consideration fosters a positive user experience, making it accessible even for those with limited technical expertise.

In summary, the Siemens PSFR-CP41 is an advanced industrial automation component characterized by its exceptional compatibility, robust processing capabilities, and comprehensive diagnostic features. Its ability to facilitate seamless communication between various devices and systems positions it as a crucial resource for enhancing operational efficiency and productivity in various industrial settings. With a focus on reliability and user-friendliness, the PSFR-CP41 marks a significant advancement in the field of automation technology.