Siemens PSFR-CP41 manual Addressing, Structures and Operation

Page 64

Appendix B

 

 

Addressing, Structures and Operation

 

 

 

 

 

 

 

0:0x01

21:0x2E

42:0x52

 

63:0x74

84:0xA6

105:0xC9

 

 

 

 

 

 

 

1:0x02

22:0x31

43:0x53

 

64:0x75

85:0xA7

106:0xCA

 

 

 

 

 

 

 

2:0x04

23:0x32

44:0x54

 

65:0x76

86:0xA9

107:0xCB

 

 

 

 

 

 

 

3:0x08

24:0x33

45:0x55

 

66:0x79

87:0xAA

108:0xCC

 

 

 

 

 

 

 

4:0x0F

25:0x34

46:0x56

 

67:0x7A

88:0xAB

109:0xCD

 

 

 

 

 

 

 

5:0x10

26:0x35

47:0x59

 

68:0x7C

89:0xAC

110:0xCE

 

 

 

 

 

 

 

6:0x17

27:0x36

48:0x5A

 

69:0x80

90:0xAD

111:0xD1

 

 

 

 

 

 

 

7:0x18

28:0x39

49:0x5C

 

70:0x81

91:0xAE

112:0xD2

 

 

 

 

 

 

 

8:0x1B

29:0x3A

50:0x63

 

71:0x82

92:0xB1

113:0xD3

 

 

 

 

 

 

 

9:0x1D

30:0x3C

51:0x65

 

72:0x84

93:0xB2

114:0xD4

 

 

 

 

 

 

 

10:0x1E

31:0x43

52:0x66

 

73:0x88

94:0xB3

115:0xD5

 

 

 

 

 

 

 

11:0x1F

32:0x45

53:0x67

 

74:0x8F

95:0xB4

116:0xD6

 

 

 

 

 

 

 

12:0x23

33:0x46

54:0x69

 

75:0x90

96:0xB5

117:0xD9

 

 

 

 

 

 

 

13:0x25

34:0x47

55:0x6A

 

76:0x97

97:0xB6

118:0xDA

 

 

 

 

 

 

 

14:0x26

35:0x49

56:0x6B

 

77:0x98

98:0xB9

119:0xDC

 

 

 

 

 

 

 

15:0x27

36:0x4A

57:0x6C

 

78:0x9B

99:0xBA

120:0xE0

 

 

 

 

 

 

 

16:0x29

37:0x4B

58:0x6D

 

79:0x9D

100:0xBC

121:0xE1

 

 

 

 

 

 

 

17:0x2A

38:0x4C

59:0x6E

 

80:0x9E

101:0xC3

122:0xE2

 

 

 

 

 

 

 

18:0x2B

39:0x4D

60:0x71

 

81:0x9F

102:0xC5

123:0xE4

 

 

 

 

 

 

 

19:0x2C

40:0x4E

61:0x72

 

82:0xA3

103:0xC6

124:0xE8

 

 

 

 

 

 

 

20:0x2D

41:0x51

62:0x73

 

83:0xA5

104:0xC7

125:0xEF

 

 

 

 

 

 

 

Arbitrated Loop Node number to ALPA lookup table

U42093-J-Z716-1-74

Operating Manual

Image 64
Contents Fibre Channel to Scsi Router PSFR-CP41 Comments… Suggestions… Corrections… Copyright and TrademarksIntroducing the PSFR-CP41 Features FeaturesFibre Channel Features Configuration Features Scsi Bus FeaturesManagement Features Specifications Point-to-Point PSFR-CP41 BenefitsIntroducing the PSFR-CP41 Multi-Initiator Single InitiatorPSFR-CP41 Benefits Availability ConnectivityDistance PerformanceHow the PSFR-CP41 Works How the PSFR-CP41 WorksOperating as Both a Scsi and Fibre Channel Device Scsi SideFibre Channel Side Mapping DevicesProcessing Scsi Information Processing Scsi InformationProcessing Fibre Channel Information Location Installing the PSFR-CP41Unpacking the Box Mounting the PSFR-CP41 in a Rack Materials neededRequired tools Mounting the PSFR-CP41 in a RackInstallation Procedure Installing the PSFR-CP41Mounting the PSFR-CP41 in a Rack Mounting at front of rack Mounting the PSFR-CP41 in a Rack Installing the PSFR-CP41 Interfaces and Connections ScsiFibre Channel Connection Scsi Connection PSFR-CP41 Scsi connection Ethernet Connection Serial Port Connection Autobaud Feature Connecting the Power Cord MIB Fibre Channel Interface Information Management Information Base MIBManagement Information Base MIB MIB Scsi Interface Information MIB Ethernet and Serial Interfaces InformationUnderstanding the PSFR-CP41 Configuration Understanding the PSFR-CP41 Configuration Soft Addressing General Fibre Channel ConfigurationHard Addressing General Scsi Configuration Fibre Channel Host to Scsi Target ConfigurationAddress Mapping Indexed AddressingIndexed Addressing Scsi BustargetlunAuto Addressing SCC AddressingConfiguring the PSFR-CP41 Operation Indicators Operation IndicatorsFault EthernetHost Device Configuration Device Management SerialEthernet/Web-Browser Device ManagementType Setting Configuring the PSFR-CP41Communicating with the PSFR-CP41 Setting Up Serial Port Communications Setting Up Serial Port CommunicationsPower Up Menu Baud Rate Configuration Perform ConfigurationPerform Configuration Fibre Channel Configuration Scsi ConfigurationEthernet Configuration Fibre Channel-to-SCSI Mapping ConfigurationSCSI-to-Fibre Channel Mapping Configuration This is not used in Siemens ConfigurationsRestore Last Saved Configuration Save ConfigurationReset Configuration to Factory Defaults Display Post Status Display Trace and Assertion HistoryReboot RebootDownload Firmware To download firmwareDowloading a new revision of the firmware Configuring the PSFR-CP41’s Ethernet Port Snmp Configuration Toggle TrapSnmp Configuration with Traps Enabled Snmp Configuration with Traps EnabledGET and SET Community Names IP Address for TrapsTroubleshooting IndicatorsBasic Verification Troubleshooting Verify Scsi Bus ConfigurationBasic Verification Verify Fibre Channel Connection Verify ConfigurationVerify Scsi Devices in NT Verify Host Configuration RS-232 Port ProblemsVerify Addressing Verify DevicesRunning Diagnostics Contact Siemens supportRJ-11 Serial and RJ-45 Ethernet Pin Assignments Appendix aPin No Function Appendix B Addressing, Structures and OperationAddressing, Structures and Operation Codes DescriptionAddressing, Structures and Operation SCC Addressing Option SCC Addressing OptionIndexed Addressing Option Appendix BAuto Assigned Addressing Option Auto Assigned Addressing OptionAppendix C Reference StandardsGlossary Fault LED ClustersDevice DifferentialFC Adapter FC DeviceFC Port FC-SCSI Hardware Path IDFibre Channel FC Fibre Channel Arbitrated Loop FC-ALFibre Channel Protocol for Scsi FCP FrameInitiator LinkLongwave Loop AddressMapping Table MultiplexerMotherboard NPortPower On Self Test Post Reset ScsiOnline OriginatorSCC Addressing Scsi AdapterScsi Addressing Scsi BusScsi Status ShortwaveSpeed TargetTopology TrapView Node Name View Port NameEnvironmental protection Environmentally friendly product design and developmentTake-back, recycling and disposal Tel. +49 5251 Fax. +49 5251Further information on environmental protection Augsburg Tel. +49 821 Fax. +49 821Comments Suggestions Corrections

PSFR-CP41 specifications

The Siemens PSFR-CP41 is a sophisticated device designed for applications in industrial automation and control systems. It serves as an essential component for monitoring and managing the functionalities of programmable logic controllers (PLCs) and other automation devices. The PSFR-CP41's main features include its robust construction, versatility, and advanced communication capabilities, making it a favored choice for engineers and system integrators worldwide.

One of the standout characteristics of the PSFR-CP41 is its compatibility with various Siemens automation systems, enhancing its flexibility in diverse applications. It supports multiple communication protocols, allowing seamless integration into existing infrastructure. This compatibility ensures that users can upgrade their facilities without extensive modifications, providing a cost-effective solution for companies looking to modernize their systems.

The PSFR-CP41 also boasts advanced processing power, enabling it to handle complex tasks efficiently. Its real-time data processing capability ensures that critical information is delivered promptly, facilitating quick decision-making processes in dynamic environments. Furthermore, its high level of reliability is crucial for industrial applications where downtime can lead to significant losses.

In terms of connectivity, the PSFR-CP41 is equipped with multiple input/output (I/O) ports, which facilitates interaction with a wide range of sensors and actuators. This feature allows the device to be deployed in various scenarios, from simple monitoring tasks to intricate control mechanisms in manufacturing plants.

Another notable technology integrated into the PSFR-CP41 is its ability to perform diagnostics and troubleshooting. The device can identify faults and provide detailed reports, enabling maintenance teams to address issues proactively. This diagnostic capability minimizes downtime and enhances operational efficiency.

The user interface of the PSFR-CP41 is designed for ease of use, featuring intuitive controls and clearly defined indicators. This design consideration fosters a positive user experience, making it accessible even for those with limited technical expertise.

In summary, the Siemens PSFR-CP41 is an advanced industrial automation component characterized by its exceptional compatibility, robust processing capabilities, and comprehensive diagnostic features. Its ability to facilitate seamless communication between various devices and systems positions it as a crucial resource for enhancing operational efficiency and productivity in various industrial settings. With a focus on reliability and user-friendliness, the PSFR-CP41 marks a significant advancement in the field of automation technology.