American Standard 7440.101 Test Installed Fitting, With Handle 1 in OFF position, turn on Water

Page 4
M 9 6 5 2 2 7

10 TEST INSTALLED FITTING

With HANDLE (1) in OFF position, turn on WATER

OFF

 

SUPPLIES (2) and check all connections for leaks.

 

 

ON

 

 

Remove AERATOR (3).

HOT

COLD

 

Operate HANDLE (1) to flush water lines thoroughly.

3

Replace AERATOR (3).

 

 

1

CHECK DRAIN CONNECTIONS

 

 

Operate POP-UP KNOB (4) and fill lavatory with water.

 

 

Check that DRAIN STOPPER (5) makes a good seal

 

 

and retains water in SINK. If DRAIN STOPPER (5)

 

 

does not seal properly, please refer to Troubleshooting

5

 

section in these instructions.

 

 

 

 

 

Release POP-UP KNOB (4) down and check all drain

 

 

connections and "P" trap for leaks. Tighten

 

 

if necessary.

 

 

 

 

 

 

WASTE

 

 

 

OUTLET

 

 

2

 

 

 

“P” TRAP

2

11 SERVICE CAUTION

Turn off hot and cold water

 

 

supplies before beginning.

 

 

To remove or replace cartidge: Fig. A.

Turn valve to OFF position.

Remove HANDLE SCREW (2).

Pull off HANDLE (3) and CAP (4).

Unthread CARTRIDGE NUT (5) and remove.

Pull out CARTEIDGE (6).

Inspect CARTRIDGE (6) and O-RING (7) for debris and clean if necessary.

Clean MANIFOLD (1) and rinse clean.

Reinstall CARTRIDGE (6) and O-RING (7) onto MANIFLOD (1).

Reinstall CARTRIDGE NUT (5), CAP (4) and HANDLE ASSEMBLY (3).

If spout drips, operate handle several times from OFF to ON and HOT to COLD position. Do not force handles.

7 6

5 4 3

1

2

2.5mm HEX KEY

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

4

Image 4
Contents Installation Instructions QUENTIN7440.101 Install FaucetMonoblock Lavatory Faucet with Speed Connect DrainInstall POP-UP Drain Install Drain from Tighten Locknut Below FixtureRemove Flange Flange Gasket and POP-UP KnobCheck Operation of POP-UP Attach Cable ConnectorMake Water Supply and Waste Connections Test Installed Fitting Service CautionWith Handle 1 in OFF position, turn on Water Check Drain ConnectionsTroubleshooting Guide Cable Adjustment ProcedureFollow Cable Adjustment Procedure Follow Stopper Removal ProcedureUnlocked Mode Locked Mode Vandal Proof7440.101 Model Number